Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
BACKGROUND: Endoscopic biliary decompression using bilateral self-expandable metallic stent (SEMS) placed using the stent-in-stent (SIS) technique is considered favorable for unresectable malignant hilar biliary obstruction (MHBO). However, occlusion of the bilateral SIS placement is frequent and revision can be challenging. This study was performed to investigate the efficacy, the long-term patency and the appropriate approach for revision of occluded bilateral SIS placement in unresectable MHBO.
METHODS: From January 2011 to July 2016, thirty-eight patients with unresectable MHBO underwent revision of occluded bilateral SIS placement. Clinical data including success rates and patency of revision, were retrospectively analyzed.
RESULTS: The technical success rate of revision was 76.3%. The clinical success rate of revision was 51.7% and mean patency of revision was 49.1 days. No significant predictive factor for clinical failure of revision was observed. The cell size of SEMS was not found to have significant effects on clinical success rates or revision patency.
CONCLUSIONS: Revision of occluded bilateral SIS placement for MHBO showed fair patency and clinical success rate. Revision method and cell size of SEMS were not found to influence clinical outcomes.
METHODS: From January 2011 to July 2016, thirty-eight patients with unresectable MHBO underwent revision of occluded bilateral SIS placement. Clinical data including success rates and patency of revision, were retrospectively analyzed.
RESULTS: The technical success rate of revision was 76.3%. The clinical success rate of revision was 51.7% and mean patency of revision was 49.1 days. No significant predictive factor for clinical failure of revision was observed. The cell size of SEMS was not found to have significant effects on clinical success rates or revision patency.
CONCLUSIONS: Revision of occluded bilateral SIS placement for MHBO showed fair patency and clinical success rate. Revision method and cell size of SEMS were not found to influence clinical outcomes.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app