Add like
Add dislike
Add to saved papers

Imaging alone versus microelectrode recording-guided targeting of the STN in patients with Parkinson's disease.

OBJECTIVEThe clinical results of deep brain stimulation (DBS) of the subthalamic nucleus (STN) are highly dependent on accurate targeting and target implantation. Several targeting tactics are in current use, including image-only and/or electrophysiologically guided approaches using microelectrode recordings (MERs). The purpose of the present study was to make an appraisal of imaging only-based versus imaging with the addition of intraoperative MER-guided STN electrode targeting.METHODSThe authors evaluated 100 consecutive patients undergoing STN DBS. The position of the STN target was estimated from preoperative MR images (direct target) or in relation to the position of the anterior and posterior commissures (indirect target). MERs were obtained for each trajectory. The authors tracked which targets were adjusted intraoperatively as a consequence of MER data. The final placement of 182 total STN electrodes was validated by intraoperative macrostimulation through the implanted DBS electrodes. The authors compared the image-based direct, indirect, MER-guided target adjustments and the final coordinates of the electrodes as seen on postoperative MRI.RESULTSIn approximately 80% of the trajectories, there was a good correspondence between the imaging-based and the MER-guided localization of the STN target. In approximately 20% of image-based targeting trajectories, however, the electrophysiological data revealed that the trajectory was suboptimal, missing the important anatomical structures to a significant extent. The greatest mismatch was in the superior-inferior axis, but this had little impact because it could be corrected without changing trajectories. Of more concern were mismatches of 2 mm or more in the mediolateral (x) or anteroposterior (y) planes, discrepancies that necessitated a new targeting trajectory to correct for the mis-targeting. The incidence of mis-targetting requiring a second MER trajectory on the first and second sides was similar (18% and 22%).CONCLUSIONSAccording to the present analysis, approximately 80% of electrodes were appropriately targeted using imaging alone. In the other 20%, imaging alone led to suboptimal targeting that could be corrected by a trajectory course correction guided by the acquired MER data. The authors' results suggest that preoperative imaging is insufficient to obtain optimal results in all patients undergoing STN DBS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app