Add like
Add dislike
Add to saved papers

Development of a method for the determination of hydromorphone in plasma by LC-MS.

A simple high-performance liquid chromatography method for the determination of hydromorphone in small volume plasma has been developed. Following solid-phase extraction using Oasis HLB cartridges, samples were separated by reverse-phase high-performance liquid chromatography on an Atlantis T3 4.6 × 150 mm column (3.0 μm) and quantified using mass spectrometry. The mobile phase was a mixture of water with 0.1% formic acid and acetonitrile with 0.1% formic acid (91:9). The standard curve ranged from 1 to 500 ng/mL. Intra- and Inter-assay variability for hydromorphone was <10%, and the average recovery was >90%. The LLOQ was 1 ng/mL. This method was successfully applied to the analysis of hydromorphone samples at this institution. This method could be useful to those investigators dealing with small sample volumes, particularly when conducting pharmacokinetic studies that require multiple sampling from the same animal.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app