Add like
Add dislike
Add to saved papers

The effect of haemodynamic and peripheral vascular variability on cardiac output monitoring: thermodilution and non-invasive pulse contour cardiac output during cardiothoracic surgery.

Anaesthesia 2018 December
While haemodynamic variability interferes with the assumption of constant flow underlying thermodilution cardiac output calculation, variability in (peripheral) arterial vascular physiology may affect pulse contour cardiac output methods. We compared non-invasive finger arterial pressure-derived continuous cardiac output measurements (Nexfin® ) with cardiac output measured using thermodilution during cardiothoracic surgery and determined the impact of cardiovascular variability on either method. We compared cardiac output derived from non-invasive finger arterial pressure with cardiac output measured by thermodilution at four grades (A-D) of cardiovascular variability. We defined Grade A data as heart rate and mean arterial pressure variability < 5% and the absence of arrhythmias (implying stable flow) and Physiocal® interval (as measure of variability in finger arterial physiology) > 30 beats. Grade B included all levels of heart rate/mean arterial pressure variability and arrhythmias (Physiocal < 30 excluded). Grade C included all Physiocal intervals (heart rate/mean arterial pressure variability > 5% and arrhythmias excluded). Grade D included all data. Comparison results were quantified as percentage errors. We analysed measurements in 27 patients undergoing coronary artery bypass surgery. Before extracorporeal circulation, the percentage error was 23% (n = 14 patients) in grade A, 28% (n = 20) in grade B, 32% (n = 22) in grade C and 37% (n = 26) in grade D, with a significant increase in variance (p = 0.035). Bias did not differ between grades. After extracorporeal circulation (n = 27), percentage errors became larger, but were not different between grades. Variability during cardiothoracic surgery affected the comparison between thermodilution and non-invasive finger arterial pressure-derived cardiac output. When the main sources of variability were included, percentage errors were large. Future cardiac output methodology comparison studies should report haemodynamic variability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app