Add like
Add dislike
Add to saved papers

Reliability evaluation of four different assays for therapeutic drug monitoring of infliximab levels.

Background: The aim of this study was to evaluate reliability of four different assays for measuring infliximab trough levels and antibodies to infliximab (ATI).

Methods: In this non-interventional, cross-sectional study including IBD patients, infliximab levels and ATI were measured using four different assays: Lisa-Tracker, Promonitor, Q-Inflixi and Sanquin. Reliability and agreement for infliximab levels was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Qualitative agreement for infliximab (based on a pre-established target window of trough levels between 3 µg/ml and 7 µg/ml) and for ATI were estimated by Cohen's kappa.

Results: Serum samples of 84 IBD patients were evaluated for infliximab using the four assays. Reliability was 'substantial' between Lisa-Tracker versus Promonitor and 'almost perfect' between the remaining assay pairs, with ICCs [95% confidence interval (CI)] ranging from 0.93 (0.70-0.97) for Lisa-Tracker versus Promonitor to 0.97 (0.95-0.98) for Q-Inflixi versus Sanquin. Bland-Altman plots showed significant bias between assays except Promonitor versus Q-Inflixi, which had excellent agreement. The greatest differences in mean infliximab were found between Promonitor versus Lisa-Tracker (-0.91 µg/ml) and Lisa-Tracker versus Q-Inflixi (0.69 µg/ml). Qualitative agreement for infliximab was 'almost perfect' for Promonitor versus Q-Inflixi (kappa 0.84) and Q-Inflixi versus Sanquin (kappa 0.81), and 'substantial' for the remaining pairs. More than 10% of patients who had infliximab levels within the target interval by Lisa-Tracker had suboptimal concentrations (<3 µg/ml) with Promonitor and Q-Inflixi. Furthermore, 11% of patients within the target interval by Q-Inflixi had supra-optimal levels (>7 µg/ml) by Lisa-Tracker. In the remaining paired comparisons, fewer than 5% of patients were placed in different subgroups. Qualitative agreement for ATI fluctuated between 'moderate' and 'almost perfect'.

Conclusions: All four assays seem suitable for therapeutic drug monitoring of infliximab. Promonitor and Q-Inflixi had the best agreement, making those assays fully interchangeable. Systematic biases between Lisa-Tracker with Promonitor and Q-Inflixi suggest that these assays should not be interchanged during the follow up of an individual patient.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app