Novel Electrocardiographic Criteria for Real-Time Assessment of Anterior Mitral Line Block: "V 1 Jump" and "V 1 Delay".

OBJECTIVES: This study hypothesized that P-wave morphology and timing under left atrial appendage (LAA) pacing change characteristically immediately upon anterior mitral line (AML) block.

BACKGROUND: Perimitral flutter commonly occurs following ablation of atrial fibrillation and can be cured by an AML. However, confirmation of bidirectional block can be challenging, especially in severely fibrotic atria.

METHODS: The study analyzed 129 consecutive patients (66 ± 8 years, 64% men) who developed perimitral flutter after atrial fibrillation ablation. We designed electrocardiography criteria in a retrospective cohort (n = 76) and analyzed them in a validation cohort (n = 53).

RESULTS: Bidirectional AML block was achieved in 110 (85%) patients. For ablation performed during LAA pacing without flutter (n = 52), we found a characteristic immediate V1 jump (increase in LAA stimulus to P-wave peak interval in lead V1 ) as a real-time marker of AML block (V1 jump ≥30 ms: sensitivity 95%, specificity 100%, positive predictive value 100%, negative predictive value 88%). As V1 jump is not applicable when block coincides with termination of flutter, absolute V1 delay was used as a criterion applicable in all cases (n = 129) with a delay of 203 ms indicating successful block (sensitivity 92%, specificity 84%, positive predictive value 90%, negative predictive value 87%). Furthermore, an initial negative P-wave portion in the inferior leads was observed, which was attenuated in case of additional cavotricuspid isthmus ablation. Computational P-wave simulations provide mechanistic confirmation of these findings for diverse ablation scenarios (pulmonary vein isolation ± AML ± roof line ± cavotricuspid isthmus ablation).

CONCLUSIONS: V1 jump and V1 delay are novel real-time electrocardiography criteria allowing fast and straightforward assessment of AML block during ablation for perimitral flutter.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app