Add like
Add dislike
Add to saved papers

Laser-Induced CO 2 Generation from Gold Nanorod-Containing Poly(propylene carbonate)-Based Block Polymer Micelles for Ultrasound Contrast Enhancement.

Poly(propylene carbonate) (PPC) decomposes at high temperature to release CO2 . This CO2 -generation temperature of PPC can be reduced down to less than 80 °C with the aid of a photoacid generator (PAG). In the present work, we demonstrate that using an additional helper component, surface plasmonic gold nanorods (GNRs), the PPC degradation reaction can also be initiated by infrared (IR) irradiation. For this purpose, a PPC-containing nanoparticle formulation was developed in which PPC-based amphiphilic block copolymers (BCPs), poly(poly(ethylene glycol) methacrylate- b-propylene carbonate- b-poly(ethylene glycol) methacrylate) (PPEGMA-PPC-PPEGMA), were self-assembled with GNRs and PAG molecules via solvent exchange. Under IR irradiation, GNRs produce heat that can cause PPC to decompose into CO2 , and PAG (after UV pretreatment) catalyzes this PPC degradation process. Two PPEGMA-PPC-PPEGMA materials were used for this study: PPEGMA7.3K -PPC5.6K -PPEGMA7.3K ("G7C6G7") and PPEGMA2.1K -PPC5.6K -PPEGMA2.1K ("G2C6G2"). Addition of CTAB-coated GNRs dispersed in water to a G2C6G2 solution in DMF produced individually G2C6G2-encapsulated GNRs, whereas the same solvent exchange procedure resulted in the formation of polymer-coated GNR clusters when G7C6G7 was used as the encapsulating material. GNR/G2C6G2 NPs exhibited a surface plasmon resonance peak at 697 nm. The clustered morphology of G7C6G7-encapsulated GNRs caused a blue shift of the absorbance maximum to 511 nm. As a consequence, GNR/G2C6G2 NPs showed a greater absorbance/heat generation rate under IR irradiation than did GNR/G7C6G7 NPs. The IR-induced CO2 generation rate was about 4.2 times higher with the GNR/G2C6G2+PAG sample than that with the GNR/G7C6G7+PAG sample. Both GNR/G7C6G7+PAG and GNR/G2C6G2+PAG systems produced ultrasound contrast enhancement effects under continuous exposure to IR light for >20 min; contrast enhancement was more spatially uniform for the GNR/G2C6G2+PAG sample. These results support the potential utility of PPC as a CO2 -generating contrast agent in ultrasound imaging applications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app