Clinical comparison of Kedo-S paediatric rotary files vs manual instrumentation for root canal preparation in primary molars: a double blinded randomised clinical trial.
European Archives of Paediatric Dentistry : Official Journal of the European Academy of Paediatric Dentistry 2018 August
AIM: This was to compare and evaluate the instrumentation time and quality of obturation between paediatric rotary file (Kedo-S) and manual instrumentation techniques in primary molars.
METHODS: A double blinded randomised control trial was performed that included mandibular primary molars in children of age 4-7 years with pulp necrosis. Sixty primary mandibular molars were randomly divided into two groups: 30 were instrumented with paediatric rotary files Kedo-S (experimental group) and 30 with hand K-files (control group). During the preparation of the primary root canals the instrumentation time was recorded in seconds. The quality of obturation was recorded as optimal, under filled or over filled using immediate post-operative radiographs. The instrumentation time and quality of obturation were analysed using independent t-test and Chi-square test.
RESULTS: Mean instrumentation time with paediatric rotary files Kedo-S (78.53 s) was significantly less than K-files (95.46 s) (p < 0.05). There was a significant improvement in the quality of obturation (p < 0.05) with paediatric rotary files (Kedo-S).
CONCLUSION: Clinical use of paediatric rotary files Kedo-S was effective during root canal preparation of primary teeth with reduction in instrumentation time and better quality of obturation.
METHODS: A double blinded randomised control trial was performed that included mandibular primary molars in children of age 4-7 years with pulp necrosis. Sixty primary mandibular molars were randomly divided into two groups: 30 were instrumented with paediatric rotary files Kedo-S (experimental group) and 30 with hand K-files (control group). During the preparation of the primary root canals the instrumentation time was recorded in seconds. The quality of obturation was recorded as optimal, under filled or over filled using immediate post-operative radiographs. The instrumentation time and quality of obturation were analysed using independent t-test and Chi-square test.
RESULTS: Mean instrumentation time with paediatric rotary files Kedo-S (78.53 s) was significantly less than K-files (95.46 s) (p < 0.05). There was a significant improvement in the quality of obturation (p < 0.05) with paediatric rotary files (Kedo-S).
CONCLUSION: Clinical use of paediatric rotary files Kedo-S was effective during root canal preparation of primary teeth with reduction in instrumentation time and better quality of obturation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app