Add like
Add dislike
Add to saved papers

Simultaneous Determination of Amphetamine-Related New Psychoactive Substances in Urine by Gas Chromatography-Mass Spectrometry.

Despite the efforts to prevent the spread of new psychoactive substances (NPS) such as synthetic amphetamine derivatives, it is apparent that newer types of NPS are still emerging on the market in recent years. Due to high potential for their abuse, reliable analytical methods are required to determine these substances in biological samples. The objective of this study was to develop and validate the gas chromatography-mass spectrometric (GC-MS) method for the simultaneous determination of 13 amphetamine-related NPS (amphetamine; AP, 4-fluoroamphetamine; 4FA, methamphamine; MA, 4-fluoromethamphetamine; 4FMA, 4-chloroamphetamine; 4CA, para-methoxyamphetamine; PMA, 4-chloromethamphetamine; 4CMA, 6-(2-aminopropyl)benzofuran; 6APB, 4-methylenedioxyamphetamine; MDA, para-methoxymethamphetamine; PMMA, 6-(2-methylaminopropyl)benzofuran; 6MAPB, 3,4-methylenedioxymethamphetamine; MDMA, 5,6-methylenedioxy-2-aminoindane; MDAI) in urine. The analytes were extracted at pH 7.4 by liquid-liquid extraction prior to their trifluoroacetyl derivatives and then analyzed by GC-MS. The validation parameters included selectivity, linearity, lower limits of quantification (LLOQ), intra and interday precision and accuracy, recovery and stability. The linear ranges were 2-100 ng/mL for AP, 4FA, 4FMA, 4CA, PMA, 6APB, MDA, and MDAI, 2-250 ng/mL for 4CMA, PMMA, and 6MAPB and 25-1,000 ng/mL for MA and MDMA, with acceptable coefficients of determination (r2 > 0.9963). The intra and interday precision were within 11.9 and 12.5%, while the intra and interday accuracies ranged from -10.6% to 13.0% and -11.0% to 6.8% for the nominal concentration at all studied levels, respectively. The LLOQs for each analyte were 2.0-25 ng/mL. The recoveries ranged from 69.3% to 96.4%. The short- and long-term variations of the analytes in urine were lower than 8.5 and 12.7%, indicating that the analytes are stable at least for 16 h at room temperature and for 7 days at 4°C, respectively. The applicability of the method was examined by analyzing urine samples from drug abusers and was determined to be effective for detecting multiple drug use.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app