Debris Heterogeneity Across Different Valve Types Captured by a Cerebral Protection System During Transcatheter Aortic Valve Replacement.

OBJECTIVES: This study investigated differences between transcatheter heart valve (THV) types and regarding debris captured by a cerebral embolic protection system (Claret Medical Sentinel, Santa Rosa, California).

BACKGROUND: Differences of THV types and cerebral injury after transcatheter aortic valve replacement (TAVR) are not well understood.

METHODS: A total of 246 patients pooled from 2 prospective studies (SENTINEL [Cerebral Protection in Transcatheter Aortic Valve Replacement] trial, N = 100; SENTINEL-H [Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement] trial, N = 146) were included in the analysis. Histopathologic assessment and histomorphometric analyses of debris were compared with THV types. Analyses were differentiated by particle size (≥150, ≥500, and ≥1,000 μm), particle count, total particle area, and maximum of largest dimension. Only commercially available THVs were included: 16% Evolut R (EvR), 15% Lotus, 59% SAPIEN 3 (S3), and 10% SAPIEN XT (XT).

RESULTS: Particles were captured in 99% of patients. There was a significantly higher amount of debris related to the vascular bed (valve tissue, arterial wall, calcification) in EvR patients compared with S3 patients; 53% of all patients irrespective of valve type had at least 1 particle ≥1 mm. Larger particles (≥500 and ≥1,000 μm) were significantly more frequent in EvR than XT and S3 patients. Lotus patients with particles ≥1,000 μm were significantly more frequent than in S3 patients. Particle count, total particle area, and maximum of largest dimension were significantly higher in both Lotus and EvR patients compared with S3 and XT.

CONCLUSIONS: Debris was captured in 99% of patients, of whom 53% had at least 1 particle of debris >1 mm. The number and size of particles captured during a procedure in which EvR or Lotus THV was used were higher and larger than with a Sapien THV. Regardless, embolic debris, including large particles, is universal across valve types and provides mechanistic support for the potential benefit of using cerebral embolic protection in all TAVR procedures.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app