Add like
Add dislike
Add to saved papers

Novel mandibular advancement bite block with supplemental oxygen to both nasal and oral cavity improves oxygenation during esophagogastroduodenoscopy: a bench comparison.

Drug-induced respiratory depression is a major cause of serious adverse events. Adequate oxygenation is very important during sedated esophagogastroduodenoscopy (EGD). Nasal breathing often shifts to oral breathing during open mouth EGD. A mandibular advancement bite block was developed for EGD using computer-assisted design and three-dimensional printing techniques. The mandible is advanced when using this bite block to facilitate airway opening. The device is composed of an oxygen inlet with one opening directed towards the nostril and another opening directed towards the oral cavity. The aim of this bench study was to compare the inspired oxygen concentration (FiO2 ) provided by the different nasal cannulas, masks, and bite blocks commonly used in sedated EGD. A manikin head was connected to one side of a two-compartment lung model by a 7.0 mm endotracheal tube with its opening in the nasopharyngeal position. The other compartment was driven by a ventilator to mimic "patient" inspiratory effort. Using this spontaneously breathing lung model, we evaluated five nasal cannulas, two face masks, and four new oral bite blocks at different oxygen flow rates and different mouth opening sizes. The respiratory rate was set at 12/min with a tidal volume of 500 mL and 8/min with a tidal volume of 300 mL. Several Pneuflo resistors of different sizes were used in the mouth of the manikin head to generate different degrees of mouth opening. FiO2 was evaluated continuously via the endotracheal tube. All parameters were evaluated using a Datex anesthesia monitoring system. The mandibular advancement bite block provided the highest FiO2 under the same supplemental oxygen flow. The FiO2 was higher for devices with oxygen flow provided via an oral bite block than that provided via the nasal route. Under the same supplemental oxygen flow, the tidal volume and respiratory rate also played an important role in the FiO2 . A low respiratory rate with a smaller tidal volume has a relative high FiO2 . The ratio of nasal to oral breathing played an important role in the FiO2 under hypoventilation but less role under normal ventilation. Bite blocks deliver a higher FiO2 during EGD. The ratio of nasal to oral breathing, supplemental oxygen flow, tidal volume, and respiratory rate influenced the FiO2 in most of the supplemental oxygen devices tested, which are often used for conscious sedation in patients undergoing EGD and colonoscopy.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app