We have located links that may give you full text access.
PVCP-based anthropomorphic breast phantoms containing structures similar to lactiferous ducts for ultrasound imaging: A comparison with human breasts.
Ultrasonics 2018 November
The purpose of this work was to obtain an anthropomorphic phantom with acoustic properties similar to those of breast tissue, possessing lactiferous duct-like structures, which would be a first for this type of phantom. Breast lesions usually grow in glandular tissues or lactiferous ducts. Shape variations in these structures are detectable by using ultrasound imaging. To increase early diagnosis, it is important to develop computer-aided diagnosis (CAD) systems and improve medical training. Using tissue-like materials that mimic known internal structures can help achieve both of these goals. However, most breast ultrasound phantoms described in the literature emulate only fat tissues and lesion-like masses. In addition, commercially available phantoms claim to be realistic, but do not contain lactiferous duct structures. In this work, we collected reference images from both breasts of ten healthy female volunteers aged between 20 and 30 years using a 10 MHz linear transducer of a B-mode medical ultrasound system. Histograms of the grey scale distribution of each tissue component of interest, the grey level means, and standard deviations of the regions of interest were obtained. Phantoms were produced using polyvinyl chloride plastisol (PVCP) suspensions. The lactiferous duct-like structures were prepared using pure PVCP. Solid scatterers, such as alumina (mesh #100) and graphite powders (mesh #140) were added to the phantom matrix to mimic glandular and fat tissue, respectively. The phantom duct-like structure diameters observed on B-mode images (1.92 mm ± 0.44) were similar to real measures obtained with a micrometer (2.08 mm ± 0.23). The phantom ducts are easy to produce and are largely stable for at least one year. This phantom allows the researchers to elaborate the structure at their will and may be used in training and as a reference for development of CAD systems.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app