Analysis of the Marginal Fit and Dimensional Stability of Cast-to Cobalt-Chromium Implant Cylinders Cast from Different Alloys.

PURPOSE: To evaluate the influence of cobalt-chromium (Co-Cr) casting alloys' melting temperatures on the cast-to Co-Cr implant cylinders' marginal fit.

MATERIALS AND METHODS: Co-Cr alloys with different melting ranges were cast into 20 Co-Cr cylinders: 10 in a high-melting temperature (HMT) group and 10 in a low-melting temperature (LMT) group. Ten cylinders were used as received as a control group. Cylinders' marginal misfit and dimensional stability were evaluated using scanning electron microscopy (×500).

RESULTS AND CONCLUSION: HMT cylinders showed significant differences in marginal misfit (2.48 ± 1.07 μm2 ) compared to LMT (1.53 ± 0.37 μm2 ) and control (1.27 ± 0.57 μm2 ) cylinders, but there were no differences in dimensional stability. HMT Co-Cr alloys produce implant-supported prostheses with poor marginal fit.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app