Data mining investigation of the association between a limb ballistocardiogram and blood pressure.

OBJECTIVE: To investigate the association between a limb ballistocardiogram (BCG) and blood pressure (BP) based on data mining.

APPROACH: During four BP-perturbing interventions, the BCG and reference BP were measured from 23 young, healthy volunteers using a custom-manufactured wristband equipped with a MEMS accelerometer and a commercial continuous BP measurement device. Both timing and amplitude features in the wrist BCG waveform were extracted, and significant features predictive of diastolic (DP) and systolic (SP) BP were selected using stepwise linear regression analysis. The selected features were further compressed using principal component analysis to yield a small set of DP and SP predictors. The association between the predictors thus obtained and BP was investigated by multivariate linear regression analysis.

MAIN RESULTS: The predictors exhibited a meaningful association with BP. When three most significant predictors were used for DP and SP, a correlation coefficient of r  =  0.75  ±  0.03 (DP) and r  =  0.75  ±  0.03 (SP), a root-mean-squared error (RMSE) of 7.4  ±  0.6 mmHg (DP) and 10.3  ±  0.8 mmHg (SP), and a mean absolute error (MAE) of 6.0  ±  0.5 mmHg (DP) and 8.3  ±  0.7 mmHg (SP) were obtained across all interventions (mean  ±  SE). The association was consistent in all the individual interventions (r  ⩾  0.68, RMSE  ⩽  5.7 mmHg, and MAE  ⩽  4.5 mmHg for DP as well as r  ⩾  0.61, RMSE  ⩽  7.9 mmHg, and MAE  ⩽  6.4 mmHg for SP on the average). The minimum number of requisite predictors for robust yet practically realistic BP monitoring appeared to be three. The association between predictors and BP was maintained even under regularized calibration (r  =  0.63  ±  0.05, RMSE  =  9.3  ±  0.8 mmHg, and MAE  =  7.6  ±  0.7 mmHg for DP as well as r  =  0.60  ±  0.05, RMSE  =  14.7  ±  1.4 mmHg, and MAE  =  11.9  ±  1.1 mmHg for SP (mean  ±  SE)). The requisite predictors for DP and SP were distinct from each other.

SIGNIFICANCE: The results of this study may provide a viable basis for ultra-convenient BP monitoring based on a limb BCG alone.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app