Efficacy of ReBound Diathermy as a Thermal Heating Agent: A Critically Appraised Topic.

Clinical Scenario: ReBound (ReGear Life Sciences, Inc, Pittsburgh, PA) is a portable shortwave diathermy unit (SWD) used to heat tissues using the same principle as induction drum SWD. It is unclear if ReBound can vigorously (4°C) heat intramuscular tissue as efficiently as other thermal agents.

CLINICAL QUESTION: In adults (P), is ReBound diathermy (I) compared to other thermal agents (C) effective at increasing intramuscular tissue temperature by 4°C (O)? Summary of Key Findings: Three studies were included for review, all randomized crossover studies. All studies agreed ReBound does not achieve vigorous (4°C) heating effects during a 30-minute treatment to the triceps surae muscle (depth=1 and 3-cm). Studies agreed the heat generated via ReBound dissipates slower than (p<.001) or similarly to PSWD at 3 cm and faster than moist hot packs (MHP, p<.001) at 1 cm. One study found intramuscular tissue temperatures increased more with ReBound (3.69°C±1.50°C) than MHP (2.82°C±.90°C) at superficial depths (1-cm, d=.70). Two studies compared ReBound to MegaPulse II PSWD at a 3-cm depth. One found the MegaPulse II increased intramuscular tissue temperature by 4.32°C±1.79°C compared to the ReBound's 2.31°C±.87°C increase (d=1.43). The final study reported the MegaPulse II increased triceps surae muscle temperature by 3.47°C±.92°C versus ReBound at 3.08°C±1.19°C (d=.37). The combined results are an increase of 3.81±1.38°C for the MegaPulse II and 2.77±1.12°C for ReBound (d=.83). Clinical Bottom Line: Results strongly indicate ReBound should not be used for vigorous (4°C) heating effects in the triceps surae muscle at 1 and 3-cm. Clinicians can use ReBound when traveling or instead of MHP for moderate (2-3°C) heating effects at deep and superficial levels (1 and 3-cm) for large treatment areas with subcutaneous fat thickness <15 mm. Strength of Recommendation: Consistent level B findings indicate ReBound does not achieve vigorous heating effects (4°C).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app