Analysis of reversed L-loops as closing loops with anterior intrusive force.
Journal of Orthodontics 2018 September
OBJECTIVE: Intrusive forces on anterior brackets are preferable for avoiding overbite deepening. Reversing plain L-loops may create such advantageous force system during space closure.
DESIGN: Force systems of reversed L-loops were compared with T-loops at three interbracket distances (IBD).
SETTING: Computational study.
METHODS: Using finite element analysis, loop response during simulated loop-pulling was determined for plain reversed L- and T-loop configurations at three IBDs and two sizes. Force systems were calculated on both loop ends for two activation forces.
RESULTS: The 12 mm IBD reversed L-loops had almost equal M/F ratios in opposite directions at both ends. A small intrusive force was found at the canine bracket (CB). The 6 mm IBD reversed L-loops showed larger M/F ratios and extrusive forces at the premolar bracket (PB) and smaller M/F with intrusive forces at CB. The force system of 12 mm IBD T-loops showed the similar force systems as off-centered V-bends with extrusive force at CB, whilst plain 6 mm IBD T-loops showed properties similar to centered V-bends with less extrusive force at CB.
CONCLUSIONS: Reversed L closing loops placed no extrusive force on the CB end at various IBDs, indicating that reversed loops will generate an intrusive force at anterior teeth during space closure.
DESIGN: Force systems of reversed L-loops were compared with T-loops at three interbracket distances (IBD).
SETTING: Computational study.
METHODS: Using finite element analysis, loop response during simulated loop-pulling was determined for plain reversed L- and T-loop configurations at three IBDs and two sizes. Force systems were calculated on both loop ends for two activation forces.
RESULTS: The 12 mm IBD reversed L-loops had almost equal M/F ratios in opposite directions at both ends. A small intrusive force was found at the canine bracket (CB). The 6 mm IBD reversed L-loops showed larger M/F ratios and extrusive forces at the premolar bracket (PB) and smaller M/F with intrusive forces at CB. The force system of 12 mm IBD T-loops showed the similar force systems as off-centered V-bends with extrusive force at CB, whilst plain 6 mm IBD T-loops showed properties similar to centered V-bends with less extrusive force at CB.
CONCLUSIONS: Reversed L closing loops placed no extrusive force on the CB end at various IBDs, indicating that reversed loops will generate an intrusive force at anterior teeth during space closure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app