Mortality Risk Using a Pediatric Quick Sequential (Sepsis-Related) Organ Failure Assessment Varies With Vital Sign Thresholds.
Pediatric Critical Care Medicine 2018 August
OBJECTIVES: We evaluated adapting the quick Sequential (Sepsis-Related) Organ Failure Assessment score (fast respiratory rate, altered mental status, low blood pressure) for pediatric use by selecting thresholds from three commonly used definitions: Pediatric Logistic Organ Dysfunction 2, Pediatric Advanced Life Support, and International Pediatric Sepsis Consensus Conference. We examined their respective performance in identifying children who had a discharge diagnosis of infection at high risk of mortality using PICU registry data, with additional focus on the influence of age on performance.
DESIGN: Analysis of retrospective data obtained from the Virtual Pediatric Systems PICU database. The performance in predicting observed mortality was assessed for the three candidate approaches using receiver operating characteristics analysis, including age group effects.
SETTING: The Virtual Pediatric Systems database contains data on diagnosis, clinical markers, and outcomes in prospectively collected clinical records from 130 participating PICUs in the United States and Canada.
PATIENTS: Children who had a discharge diagnosis of infection in a participating PICU between 2009 and 2014, for which all required data were available.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Data from 40,228 children revealed an overall mortality of 4.22%. Area under the receiver operating characteristics curve (95% CI) was 0.760 (0.749-0.771) for Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation, 0.700 (0.689-0.712) for Pediatric Advanced Life Support, and 0.709 (0.696-0.721) for International Pediatric Sepsis Consensus Conference. When split by age group, the performance of Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation was lowest in the youngest neonates (under 1 wk old), with an area under the receiver operating characteristics curve (95% CI) of 0.724 (0.656-0.791), and in the teenagers (13-18 yr), with an area under the receiver operating characteristics curve of 0.710 (0.682-0.738), yet it still outperformed Pediatric Advanced Life Support and International Pediatric Sepsis Consensus Conference in both groups.
CONCLUSIONS: Among critically ill children who had a discharge diagnosis of infection in the PICU, quick Sequential (Sepsis-Related) Organ Failure Assessment score performs best when using the Pediatric Logistic Organ Dysfunction 2 age thresholds with mechanical ventilation, while all definitions performed worse at extremes of pediatric age. Thus, mortality risk varies with vital sign thresholds, and although Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation performed marginally better, it is unlikely to be of use to clinicians. More work is needed to develop a robust and relevant pediatric sepsis risk score.
DESIGN: Analysis of retrospective data obtained from the Virtual Pediatric Systems PICU database. The performance in predicting observed mortality was assessed for the three candidate approaches using receiver operating characteristics analysis, including age group effects.
SETTING: The Virtual Pediatric Systems database contains data on diagnosis, clinical markers, and outcomes in prospectively collected clinical records from 130 participating PICUs in the United States and Canada.
PATIENTS: Children who had a discharge diagnosis of infection in a participating PICU between 2009 and 2014, for which all required data were available.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Data from 40,228 children revealed an overall mortality of 4.22%. Area under the receiver operating characteristics curve (95% CI) was 0.760 (0.749-0.771) for Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation, 0.700 (0.689-0.712) for Pediatric Advanced Life Support, and 0.709 (0.696-0.721) for International Pediatric Sepsis Consensus Conference. When split by age group, the performance of Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation was lowest in the youngest neonates (under 1 wk old), with an area under the receiver operating characteristics curve (95% CI) of 0.724 (0.656-0.791), and in the teenagers (13-18 yr), with an area under the receiver operating characteristics curve of 0.710 (0.682-0.738), yet it still outperformed Pediatric Advanced Life Support and International Pediatric Sepsis Consensus Conference in both groups.
CONCLUSIONS: Among critically ill children who had a discharge diagnosis of infection in the PICU, quick Sequential (Sepsis-Related) Organ Failure Assessment score performs best when using the Pediatric Logistic Organ Dysfunction 2 age thresholds with mechanical ventilation, while all definitions performed worse at extremes of pediatric age. Thus, mortality risk varies with vital sign thresholds, and although Pediatric Logistic Organ Dysfunction 2 with mechanical ventilation performed marginally better, it is unlikely to be of use to clinicians. More work is needed to develop a robust and relevant pediatric sepsis risk score.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app