Add like
Add dislike
Add to saved papers

Fault tolerant system based on non-integers order observers: Application in a heat exchanger.

ISA Transactions 2018 September
This work presents a fault-tolerant (FT) scheme based on the application of non-integer order observers also called fractional observers, the case of study is a double pipe countercurrent heat exchanger (HE). The aim of the FT is to detect sensors faults as soon as possible, and to provide a healthy signal in order to replace the faulty sensor signal by the fractional observer estimation. To develop the FT scheme a bank of high gain fractional order observers (HGFOO) is proposed. The Riemann-Liouville (RL) fractional derivative definition is used to solve each fractional observer. Experimental measures from a HE were used to test the performance of the fractional observers and the control scheme. The results show the robustness of the proposed observers.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app