Virtual Functional Assessment of Coronary Stenoses Using Intravascular Ultrasound Imaging: A Proof-of-Concept Pilot Study.
Heart, Lung & Circulation 2018 March 3
AIMS: We aimed to investigate the performance of virtual functional assessment of coronary stenoses using intravascular ultrasound (IVUS)-based three-dimensional (3D) coronary artery reconstruction against the invasively measured fractional flow reserve (FFR).
METHODS AND RESULTS: Twenty-two patients with either typical symptoms of stable angina or a positive stress test, who underwent IVUS and FFR, were included in this study. Five patients presented FFR values lower than the 0.80 threshold, indicating ischaemia. IVUS-based 3D reconstruction and blood flow simulation were performed and the virtual functional assessment index (vFAI) was calculated. A strong correlation between IVUS-based vFAI and FFR was observed (Spearman correlation coefficient [rs ]=0.88, p<0.0001). There was a small overestimation of the FFR by the IVUS-based vFAI (mean difference=0.0196±0.037; p=0.023 for difference from zero). All cases with haemodynamically significant stenoses (FFR≤0.8) were correctly categorised by the IVUS-based vFAI (vFAI≤0.8).
CONCLUSION: The proposed approach allows the complete and comprehensive assessment of coronary stenoses providing anatomic and physiologic information, pre- and post-intervention, using only an IVUS catheter without the use of a pressure wire.
METHODS AND RESULTS: Twenty-two patients with either typical symptoms of stable angina or a positive stress test, who underwent IVUS and FFR, were included in this study. Five patients presented FFR values lower than the 0.80 threshold, indicating ischaemia. IVUS-based 3D reconstruction and blood flow simulation were performed and the virtual functional assessment index (vFAI) was calculated. A strong correlation between IVUS-based vFAI and FFR was observed (Spearman correlation coefficient [rs ]=0.88, p<0.0001). There was a small overestimation of the FFR by the IVUS-based vFAI (mean difference=0.0196±0.037; p=0.023 for difference from zero). All cases with haemodynamically significant stenoses (FFR≤0.8) were correctly categorised by the IVUS-based vFAI (vFAI≤0.8).
CONCLUSION: The proposed approach allows the complete and comprehensive assessment of coronary stenoses providing anatomic and physiologic information, pre- and post-intervention, using only an IVUS catheter without the use of a pressure wire.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app