We have located links that may give you full text access.
Comparison of Efficacy and Safety between First- and Second-Generation Drug-Eluting Stents in Patients with Acute Coronary Syndrome.
Chinese Medical Journal 2018 June 21
Background: It remains undetermined whether second-generation drug-eluting stents (G2-DESs) outperform first-generation DESs (G1-DESs) in patients with acute coronary syndrome (ACS). We aimed to compare the efficacy and safety of G1-DES and G2-DES in ACS patients in a high-volume cardiovascular center.
Methods: In 2013, 10,724 consecutive patients underwent percutaneous coronary intervention in our institution. We included 4037 patients with ACS who underwent exclusively G1-DES or G2-DES implantation (n = 364 and n = 3673, respectively). We used propensity score matching to minimize the imbalance between the G1-DES and G2-DES groups and followed patients for 2 years. The efficacy endpoints were major adverse cardiac events (MACEs) and its components including target vessel-related myocardial infarction (TV-MI), target vessel revascularization/target lesion revascularization (TVR/TLR), and cardiac death. The safety endpoint was stent thrombosis. Continuous variables were compared by Mann-Whitney U-test, and categorical variables were compared using Pearson's Chi-square or Fisher's exact test. Kaplan-Meier curves were constructed to compare the event-free survival rates, and multivariate Cox proportional hazards regression analysis was used to assess whether stent type was an independent risk factor for the efficacy and safety endpoints.
Results: At the 2-year follow-up, the results for MACE and it components, as well as stent thrombosis, were similar for G1-DES and G2-DES (MACE, 5.2% vs. 4.3%, χ2 = 0.514, P = 0.474; TV-MI, 0.8% vs. 0.4%, P = 0.407; TVR, 4.9% vs. 3.7%, χ2 = 0.939, P = 0.333; TLR, 3.8% vs. 2.5%, χ2 = 1.610, P = 0.205; cardiac death, 0.3% vs. 0.5%, P = 0.670; and stent thrombosis, 0.5% vs. 0.4%, P > 0.999). Kaplan-Meier analysis indicated similar event-free survival rates between G1-DES and G2-DES after propensity score matching (all: log-rank P > 0.05). Multivariate analysis demonstrated that stent type was not an independent risk factor for the efficacy and safety endpoints (MACE, hazard ratio [HR] = 0.805, 95% confidence interval [CI]: 0.455-1.424, P = 0.456; TV-MI, HR = 0.500, 95% CI: 0.101-2.475, P = 0.395; TVR, HR = 0.732, 95% CI: 0.403-1.330, P = 0.306; TLR, HR = 0.629, 95% CI: 0.313-1.264, P = 0.193; cardiac death, HR = 1.991, 95% CI: 0.223-17.814, P = 0.538; and stent thrombosis, HR = 0.746, 95% CI: 0.125-4.467, P = 0.749).
Conclusion: G1-DES and G2-DES have similar efficacy and safety profiles in ACS patients at the 2-year follow-up.
Methods: In 2013, 10,724 consecutive patients underwent percutaneous coronary intervention in our institution. We included 4037 patients with ACS who underwent exclusively G1-DES or G2-DES implantation (n = 364 and n = 3673, respectively). We used propensity score matching to minimize the imbalance between the G1-DES and G2-DES groups and followed patients for 2 years. The efficacy endpoints were major adverse cardiac events (MACEs) and its components including target vessel-related myocardial infarction (TV-MI), target vessel revascularization/target lesion revascularization (TVR/TLR), and cardiac death. The safety endpoint was stent thrombosis. Continuous variables were compared by Mann-Whitney U-test, and categorical variables were compared using Pearson's Chi-square or Fisher's exact test. Kaplan-Meier curves were constructed to compare the event-free survival rates, and multivariate Cox proportional hazards regression analysis was used to assess whether stent type was an independent risk factor for the efficacy and safety endpoints.
Results: At the 2-year follow-up, the results for MACE and it components, as well as stent thrombosis, were similar for G1-DES and G2-DES (MACE, 5.2% vs. 4.3%, χ2 = 0.514, P = 0.474; TV-MI, 0.8% vs. 0.4%, P = 0.407; TVR, 4.9% vs. 3.7%, χ2 = 0.939, P = 0.333; TLR, 3.8% vs. 2.5%, χ2 = 1.610, P = 0.205; cardiac death, 0.3% vs. 0.5%, P = 0.670; and stent thrombosis, 0.5% vs. 0.4%, P > 0.999). Kaplan-Meier analysis indicated similar event-free survival rates between G1-DES and G2-DES after propensity score matching (all: log-rank P > 0.05). Multivariate analysis demonstrated that stent type was not an independent risk factor for the efficacy and safety endpoints (MACE, hazard ratio [HR] = 0.805, 95% confidence interval [CI]: 0.455-1.424, P = 0.456; TV-MI, HR = 0.500, 95% CI: 0.101-2.475, P = 0.395; TVR, HR = 0.732, 95% CI: 0.403-1.330, P = 0.306; TLR, HR = 0.629, 95% CI: 0.313-1.264, P = 0.193; cardiac death, HR = 1.991, 95% CI: 0.223-17.814, P = 0.538; and stent thrombosis, HR = 0.746, 95% CI: 0.125-4.467, P = 0.749).
Conclusion: G1-DES and G2-DES have similar efficacy and safety profiles in ACS patients at the 2-year follow-up.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university