The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair.

PURPOSE: To evaluate the impact of suture caliber and looped configurations on the integrity of 4-strand modified Kessler zone II flexor tendon repairs during progressive cyclic loading.

METHODS: Seventy-two flexor digitorum profundus tendons from 18 fresh human cadaver hands were divided into 4 repair groups. Thirty-six matched tendons underwent repair using either a 4-0 looped or 4-0 single-stranded suture, and an additional 36 tendons underwent 3-0 looped or 3-0 single-stranded repairs. Repair strength was tested by progressive cyclic loading. The force generating 2-mm gap formation, ultimate failure, and the mechanism of failure were recorded for each test. The impact of looped versus single-stranded configurations and the effect of tendon cross-sectional area on repair integrity were analyzed for each suture caliber.

RESULTS: There was no statistically significant difference between groups regarding the force to 2-mm gap formation or ultimate failure, and all values exceeded the minimum threshold of 27 N required to withstand an early active range of motion rehabilitation protocol. The use of a 3-0 caliber suture resulted in a significantly higher proportion of repairs failing by suture pullout through the tendon substance, including 63.5% of looped and 38.9% of single-stranded core sutures. By comparison, this occurred in 11.1% of 4-0 looped and 0% of 4-0 single-stranded sutures. Larger tendon cross-sectional areas were associated with more robust repairs, particularly in the 3-0 looped group.

CONCLUSIONS: In a human cadaver flexor tendon repair model, there was no significant difference in the mean force to failure between all 4 flexor tendon repair constructs under progressive cyclic loading. However, the 3-0 caliber suture failed more frequently by suture pullout, particularly with the use of a looped suture.

CLINICAL RELEVANCE: Four-strand flexor tendon repairs using a 3-0 caliber suture are more prone to early failure by suture pullout under progressive cyclic loading compared with a 4-0 caliber suture.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app