Intracardiac Versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion: The LAAO Italian Multicenter Registry.

OBJECTIVES: This study sought to evaluate the feasibility, safety, and efficacy of intracardiac echocardiography (ICE)-guided versus transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) by the use of Amplatzer Cardiac Plug or Amulet devices included in a large Italian registry.

BACKGROUND: TEE is widely used for LAAO procedure guidance. ICE may be a potential alternative imaging modality in LAAO.

METHODS: Data from 604 LAAO procedures performed in 16 Italian centers were reviewed. ICE-guided LAAO was performed in 187 patients, whereas TEE was used in 417 patients. Procedural success was defined as LAAO without occurrence of pericardial tamponade, stroke, systemic embolism with end organ damage, major bleeding, and device embolization. Stroke, transient ischemic attack, major bleeding, overall and cardiovascular death were analyzed.

RESULTS: CHA2 DS2 -VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65 to 74 years, sex category) and HAS-BLED (hypertension, abnormal renal and liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores were similar between the ICE and TEE groups. TEE implied lower procedural (delta 12 min) and fluoroscopy time (delta 5 min) when compared with ICE. Procedural success was similarly high (≥94%) between the TEE and ICE groups with a complication rate of 6.5% for TEE versus 4.2% for ICE (odds ratio: 1.468; 95% confidence interval: 0.681 to 3.166; p = 0.327). At median follow-up of 451 days (interquartile range: 162 to 899 days), the rate of cerebral ischemic events was similar between TEE-guided and ICE-guided procedures.

CONCLUSIONS: ICE-guided LAAO by means of Amplatzer devices may represent a second alternative imaging modality after an appropriate learning curve and bearing in mind that pre-procedural computed tomography imaging is mandatory. When comparing ICE with TEE, TEE remains the gold standard.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app