We have located links that may give you full text access.
Hepatic selective internal radiation therapy: how well does pretreatment 99mTc-macroaggregated albumin activity distribution and quantification agree with post-therapy bremsstrahlung imaging?
Nuclear Medicine Communications 2018 September
AIM: The aim of this study was to examine the agreement of pretreatment Tc-macroaggregated albumin imaging performed for selective internal radiation therapy (SIRT) workup with Y percentage lung shunt (PLS) and regional hepatic distribution in subsequent post-therapy bremsstrahlung imaging.
PATIENTS AND METHODS: Planar images were used to calculate PLS. The significant Y bremsstrahlung scatter required background correction. Results using both Y lung background regions of interest (ROI) reported in previous studies and extended ROIs (reflecting lung background variation) were compared with Tc-MAA PLS. Lesion and healthy liver volumes were outlined on diagnostic computed tomography scans and registered to Tc-MAA and Y single-photon emission computed tomography/computed tomographydata. Single-photon emission computed tomography voxel values were normalized to injected Y activity. Volume mean activities were calculated, and converted into the mean absorbed dose. Agreement was quantified using Bland-Altman analysis.
RESULTS: PLS: The bias using previous studies' lung background ROIs was -10.71%, with a 95% confidence interval (CI) of -18.79 to -2.64%. The extended ROI yielded a bias of 0.77% (95% CI: -2.23 to 3.70%). Liver: The healthy liver bias was 0.01 MBq/ml (0.17 Gy), with a -0.05 to 0.06 MBq/ml (95% CI:0.80 -1.93 Gy). The lesion mean activity/ml bias was -0.02 MBq/ml (3.71 Gy), with a -0.81 to 0.76 MBq/ml (95% CI: -35.49 to 28.07 Gy).
CONCLUSIONS: The PLS agreement was sensitive to the Y lung background correction ROI, potentially explaining a previously published controversy. The mean activity and absorbed dose agreement for the metastatic lesions was poorer than the healthy liver volumes studied here.
PATIENTS AND METHODS: Planar images were used to calculate PLS. The significant Y bremsstrahlung scatter required background correction. Results using both Y lung background regions of interest (ROI) reported in previous studies and extended ROIs (reflecting lung background variation) were compared with Tc-MAA PLS. Lesion and healthy liver volumes were outlined on diagnostic computed tomography scans and registered to Tc-MAA and Y single-photon emission computed tomography/computed tomographydata. Single-photon emission computed tomography voxel values were normalized to injected Y activity. Volume mean activities were calculated, and converted into the mean absorbed dose. Agreement was quantified using Bland-Altman analysis.
RESULTS: PLS: The bias using previous studies' lung background ROIs was -10.71%, with a 95% confidence interval (CI) of -18.79 to -2.64%. The extended ROI yielded a bias of 0.77% (95% CI: -2.23 to 3.70%). Liver: The healthy liver bias was 0.01 MBq/ml (0.17 Gy), with a -0.05 to 0.06 MBq/ml (95% CI:0.80 -1.93 Gy). The lesion mean activity/ml bias was -0.02 MBq/ml (3.71 Gy), with a -0.81 to 0.76 MBq/ml (95% CI: -35.49 to 28.07 Gy).
CONCLUSIONS: The PLS agreement was sensitive to the Y lung background correction ROI, potentially explaining a previously published controversy. The mean activity and absorbed dose agreement for the metastatic lesions was poorer than the healthy liver volumes studied here.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app