Add like
Add dislike
Add to saved papers

Sleep Tracking and Exercise in Patients With Type 2 Diabetes Mellitus (Step-D): Pilot Study to Determine Correlations Between Fitbit Data and Patient-Reported Outcomes.

BACKGROUND: Few studies assessing the correlation between patient-reported outcomes and patient-generated health data from wearable devices exist.

OBJECTIVE: The aim of this study was to determine the direction and magnitude of associations between patient-generated health data (from the Fitbit Charge HR) and patient-reported outcomes for sleep patterns and physical activity in patients with type 2 diabetes mellitus (T2DM).

METHODS: This was a pilot study conducted with adults diagnosed with T2DM (n=86). All participants wore a Fitbit Charge HR for 14 consecutive days and completed internet-based surveys at 3 time points: day 1, day 7, and day 14. Patient-generated health data included minutes asleep and number of steps taken. Questionnaires assessed the number of days of exercise and nights of sleep problems per week. Means and SDs were calculated for all data, and Pearson correlations were used to examine associations between patient-reported outcomes and patient-generated health data. All respondents provided informed consent before participating.

RESULTS: The participants were predominantly middle-aged (mean 54.3, SD 13.3 years), white (80/86, 93%), and female (50/86, 58%). Use of oral T2DM medication correlated with the number of mean steps taken (r=.35, P=.001), whereas being unaware of the glycated hemoglobin level correlated with the number of minutes asleep (r=-.24, P=.04). On the basis of the Fitbit data, participants walked an average of 4955 steps and slept 6.7 hours per day. They self-reported an average of 2.0 days of exercise and 2.3 nights of sleep problems per week. The association between the number of days exercised and steps walked was strong (r=.60, P<.001), whereas the association between the number of troubled sleep nights and minutes asleep was weaker (r=.28, P=.02).

CONCLUSIONS: Fitbit and patient-reported data were positively associated for physical activity as well as sleep, with the former more strongly correlated than the latter. As extensive patient monitoring can guide clinical decisions regarding T2DM therapy, passive, objective data collection through wearables could potentially enhance patient care, resulting in better patient-reported outcomes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app