We have located links that may give you full text access.
Comparative Study
Journal Article
Improving the performance of virtual crossmatch results by correlating with nationally-performed physical crossmatches: Obtaining additional value from proficiency testing activities.
Human Immunology 2018 August
PURPOSE: When donor specific HLA antibodies (DSA) are identified, the predictive value of whether a certain strength of reactivity (mean fluorescence intensity, MFI) leads to a positive crossmatch is uncertain. To determine this, we compared the DSA MFI results we generated locally for nationally distributed proficiency samples against the percentage of other laboratories reporting a positive crossmatch.
METHOD: DSA MFI from single antigen beads reported by our laboratory for nationally-distributed proficiency testing survey samples was compared against the aggregate percentage of participating laboratories reporting the crossmatch positive using direct, antiglobulin-enhanced microcytotoxic (CDC-AHG), or flow cytometric methods from 2011 to 2015.
RESULTS: 180 surveys were analyzed. Positive CDC-AHG and flow cytometric crossmatches were associated with MFI greater than 8554 and 2748 respectively for HLA class I, and 6919 and 3707 respectively for class II. Institutional MFI less than 3000 had high positive predictive values (0.98, 0.85, 0.81) for negative direct, AHG, and flow crossmatches, while MFI greater than 8000 had high negative predictive values for a positive direct, AHG, and flow crossmatches (1.00, 1.00, 0.97).
CONCLUSION: Review of locally-generated MFI results as part of participating in proficiency testing allow for predictability of crossmatch results against other laboratories, providing a replicable model for other participating centers.
METHOD: DSA MFI from single antigen beads reported by our laboratory for nationally-distributed proficiency testing survey samples was compared against the aggregate percentage of participating laboratories reporting the crossmatch positive using direct, antiglobulin-enhanced microcytotoxic (CDC-AHG), or flow cytometric methods from 2011 to 2015.
RESULTS: 180 surveys were analyzed. Positive CDC-AHG and flow cytometric crossmatches were associated with MFI greater than 8554 and 2748 respectively for HLA class I, and 6919 and 3707 respectively for class II. Institutional MFI less than 3000 had high positive predictive values (0.98, 0.85, 0.81) for negative direct, AHG, and flow crossmatches, while MFI greater than 8000 had high negative predictive values for a positive direct, AHG, and flow crossmatches (1.00, 1.00, 0.97).
CONCLUSION: Review of locally-generated MFI results as part of participating in proficiency testing allow for predictability of crossmatch results against other laboratories, providing a replicable model for other participating centers.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app