BACKGROUND AND AIM: The aim of this study was to assess the efficacy of a new microwave ablation (MWA) system, the Emprint Ablation System, for the ablation of unresectable large liver tumors (≥ 30 mm).
METHODS: Twenty-one hepatic tumors (mean diameter, 34.7 mm) from 21 patients who underwent percutaneous MWA were included in this cross-sectional study. A volume analyzer based on computed tomography imaging was used for all patients within the month before and month after the procedure to evaluate the shape and volume of ablation zones. In addition, computed tomography imaging was performed again 3 months after the procedure to evaluate the presence of residual tumors and local recurrence.
RESULTS: Mean ablation time was 11.3 min, and mean overall procedure time was 33.4 min. An ablated adrenal gland-induced Takotsubo (stress) cardiomyopathy occurred immediately after MWA as a major complication in one patient. Roundness index A, B, and C presented a mean value of 0.94, 0.94, and 1.01, respectively (all values near 1 is a perfect sphere), indicating that a spherical ablation zone was achieved. The mean ablation volume was larger than the volume of tumors (24.5 vs 41.7 cm3 ). Residual tumors were confirmed in only 4.8% of tumors after a single ablation session. There was no local recurrence.
CONCLUSIONS: In our experience, the new MWA system provides an effective treatment option for unresectable large liver tumors. However, to ablate the liver tumors safely, it is necessary to consider the surrounding organs, such as the adrenal glands.
METHODS: Twenty-one hepatic tumors (mean diameter, 34.7 mm) from 21 patients who underwent percutaneous MWA were included in this cross-sectional study. A volume analyzer based on computed tomography imaging was used for all patients within the month before and month after the procedure to evaluate the shape and volume of ablation zones. In addition, computed tomography imaging was performed again 3 months after the procedure to evaluate the presence of residual tumors and local recurrence.
RESULTS: Mean ablation time was 11.3 min, and mean overall procedure time was 33.4 min. An ablated adrenal gland-induced Takotsubo (stress) cardiomyopathy occurred immediately after MWA as a major complication in one patient. Roundness index A, B, and C presented a mean value of 0.94, 0.94, and 1.01, respectively (all values near 1 is a perfect sphere), indicating that a spherical ablation zone was achieved. The mean ablation volume was larger than the volume of tumors (24.5 vs 41.7 cm3 ). Residual tumors were confirmed in only 4.8% of tumors after a single ablation session. There was no local recurrence.
CONCLUSIONS: In our experience, the new MWA system provides an effective treatment option for unresectable large liver tumors. However, to ablate the liver tumors safely, it is necessary to consider the surrounding organs, such as the adrenal glands.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app