We have located links that may give you full text access.
Safety and efficacy of the Derivo Embolization Device for the treatment of unruptured intracranial aneurysms: a multicentric study.
Journal of Neurointerventional Surgery 2018 May 31
BACKGROUND: The Derivo Embolization Device (DED) is a novel flow diverter stent that provides increased x-ray visibility, an improved delivery system, and potentially reduced thrombogenicity. The objective of this study was to evaluate the early safety and efficacy of the second-generation DED.
METHODS: We retrospectively analyzed all patients with unruptured intracranial aneurysms (UIAs) treated with the DED between November 2015 and December 2017 in three German tertiary care centers. Procedural details, complications, and morbidity within 30 days after treatment, as well as the aneurysm occlusion rates after 6 months (O'Kelly-Marotta scale, OKM), were evaluated.
RESULTS: Implantation of the DED was attempted in 42 patients with 42 aneurysms. All procedures were technically successful. Multiple DEDs were used in three aneurysms (7.2%) and adjunctive coiling in 11 (26.2%). Procedure-related complications occurred in four cases (9.5%) including three thromboembolic events and one aneurysm perforation. The morbidity rate was 2.4% and there was no mortality. One patient suffered an ischemic stroke with persistent aphasia at 30-day follow-up due to a thromboembolic infarct (modified Rankin Scale score 1). Among 33 patients (78.6%) available for angiographic follow-up, complete (OKM D) and favorable (OKM C+D) aneurysm occlusion was obtained in 72.7% (24/33) and 87.9% (29/33), respectively.
CONCLUSIONS: Endovascular treatment of UIAs with the DED is associated with high procedural safety and adequate occlusion rates. Examinations at 1- and 2-year follow-up will provide data on the long-term safety and angiographic outcomes of this device.
METHODS: We retrospectively analyzed all patients with unruptured intracranial aneurysms (UIAs) treated with the DED between November 2015 and December 2017 in three German tertiary care centers. Procedural details, complications, and morbidity within 30 days after treatment, as well as the aneurysm occlusion rates after 6 months (O'Kelly-Marotta scale, OKM), were evaluated.
RESULTS: Implantation of the DED was attempted in 42 patients with 42 aneurysms. All procedures were technically successful. Multiple DEDs were used in three aneurysms (7.2%) and adjunctive coiling in 11 (26.2%). Procedure-related complications occurred in four cases (9.5%) including three thromboembolic events and one aneurysm perforation. The morbidity rate was 2.4% and there was no mortality. One patient suffered an ischemic stroke with persistent aphasia at 30-day follow-up due to a thromboembolic infarct (modified Rankin Scale score 1). Among 33 patients (78.6%) available for angiographic follow-up, complete (OKM D) and favorable (OKM C+D) aneurysm occlusion was obtained in 72.7% (24/33) and 87.9% (29/33), respectively.
CONCLUSIONS: Endovascular treatment of UIAs with the DED is associated with high procedural safety and adequate occlusion rates. Examinations at 1- and 2-year follow-up will provide data on the long-term safety and angiographic outcomes of this device.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app