Add like
Add dislike
Add to saved papers

Evaluation of Predictability of Suitable Implant Lengths as related to Accurate Treatment Planning using Recent Roentgenographic Measures: A Key to Success.

BACKGROUND AND AIM: Selection of suitable length of dental implants is very subjective and largely depends on clinical evidences and operator's expertise. The present study was aimed to assess the role of cone beam computed tomography (CBCT) and cephalograms as far as the selection of right implant length is concerned.

MATERIALS AND METHODS: The study includes 220 patients for whom radiographic and follow-up records were obtained. There were 105 males and 115 females in the age range of 22 to 58 years. A total of 98 implant sites in different edentulous areas were studied. Length of implant was predicted at treatment planning and compared with finally placed implant at surgical stages. It also includes the in-depth exploration of (1) number of implants placed per patient, (2) implant per edentulous areas, (3) implant location, and (4) implant region. For prediction of implant lengths, CBCT results were obtained and compared with cephalometric findings. Accuracies of implant lengths as planned by CBCT and cephalometric images were also studied at treatment planning and surgical stages. Statistical analysis and results: Upon statistical comparisons, we found that larger implant lengths chosen at treatment planning stage did not change in 65.5% of patients. In addition, the smaller length implants were just about the same as that with larger dimensions. The CBCT results were satisfactory (up to 98.5%). Cephalometry was performed well in this prediction, especially in posterior mandible (87.9%). However, its performance in anterior maxillary region was not satisfactory (69.6%). Intergroup comparisons of CBCT and cephalometric results at different regions were significant (p < 0.001).

CONCLUSION: Our study results show insignificant changes in the length of implants that was exactly planned using CBCT scans. Therefore, accurate prediction of implant lengths can be done using CBCT scans as they have superior and advanced tools that facilitate presurgical decision-making. Lateral cephalometric evaluation has been shown as an imperative radiographic tool for determining implant lengths as it confirmed the significance bone resorption on the selection of implant length at different sites.

CLINICAL SIGNIFICANCE: The CBCT and lateral cephalogram offer excellent anatomical details that can be judiciously applied for treatment planning and other clinical decision-making, including selection of correct implant length. Our study advocates thorough cephalometric evaluations of mandible wherein implants are to be placed for implant-supported overdentures.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app