Add like
Add dislike
Add to saved papers

Evaluation of the fit of metal copings fabricated using stereolithography.

STATEMENT OF PROBLEM: Rapid prototyping, including stereolithography (SLA), is a more recent technique for fabricating metal frameworks than the conventional lost-wax technique. However, investigations of the marginal discrepancies and internal spacing of cobalt-chromium (Co-Cr) metal copings fabricated using SLA are lacking.

PURPOSE: The purpose of this in vitro study was to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of Co-Cr metal copings fabricated using the SLA technique.

MATERIAL AND METHODS: A resin tooth of a maxillary right first premolar was prepared with a deep chamfer margin for a metal-ceramic crown. Titanium master dies were milled after scanning the prepared tooth (n=45). In conventional lost wax group (group LW), the conventional lost-wax technique was used to fabricate Co-Cr metal copings (n=15). In milling group (group MC), a computer-aided design (CAD) system was used to design the metal copings, which were milled from Co-Cr alloy (n=15). The CAD system was also used to design the metal copings in a 3D-printed group (group SL), and Co-Cr metal copings were cast from resin patterns fabricated using the SLA device (n=15). Marginal discrepancies and internal spaces were measured using an optical microscope at ×100 magnification at 11 reference points. The values were analyzed statistically with 1-way analysis of variance (α=.05).

RESULTS: The mean (±SD) overall space was 63.2 ±16.6 μm for group LW, 70.2 ±15.5 μm for group SL, and 130.3 ±13.8 μm for group MC. The overall spaces differed significantly between group MC and the other 2 groups (P<.05). The marginal discrepancy and internal spaces were significantly larger in group MC than in groups LW and SL. (P<.05). Occlusal spaces differed significantly among the 3 study groups (P<.05).

CONCLUSIONS: Co-Cr metal copings fabricated using an SLA technique showed clinically acceptable marginal discrepancies and internal spaces. These spaces did not differ significantly from those obtained with the conventional lost-wax technique.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app