Objective: To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation.

Methods: A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores.

Results: The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones ( P <0.05), but there was no significant difference between at immediate after operation and last follow-up ( P >0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%.

Conclusion: 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app