Add like
Add dislike
Add to saved papers

Computer-based self-training for CT colonography with and without CAD.

European Radiology 2018 November
OBJECTIVES: To determine whether (1) computer-based self-training for CT colonography (CTC) improves interpretation performance of novice readers; (2) computer-aided detection (CAD) use during training affects learning.

METHODS: Institutional review board approval and patients' informed consent were obtained for all cases included in this study. Twenty readers (17 radiology residents, 3 radiologists) with no experience in CTC interpretation were recruited in three centres. After an introductory course, readers performed a baseline assessment test (37 cases) using CAD as second reader. Then they were randomized (1:1) to perform either a computer-based self-training (150 cases verified at colonoscopy) with CAD as second reader or the same training without CAD. The same assessment test was repeated after completion of the training programs. Main outcome was per lesion sensitivity (≥ 6 mm). A generalized estimating equation model was applied to evaluate readers' performance and the impact of CAD use during training.

RESULTS: After training, there was a significant improvement in average per lesion sensitivity in the unassisted phase, from 74% (356/480) to 83% (396/480) (p < 0.001), and in the CAD-assisted phase, from 83% (399/480) to 87% (417/480) (p = 0.021), but not in average per patient sensitivity, from 93% (390/420) to 94% (395/420) (p = 0.41), and specificity, from 81% (260/320) to 86% (276/320) (p = 0.15). No significant effect of CAD use during training was observed on per patient sensitivity and specificity, nor on per lesion sensitivity.

CONCLUSIONS: A computer-based self-training program for CTC improves readers' per lesion sensitivity. CAD as second reader does not have a significant impact on learning if used during training.

KEY POINTS: • Computer-based self-training for CT colonography improves per lesion sensitivity of novice readers. • Self-training program does not increase per patient specificity of novice readers. • CAD used during training does not have significant impact on learning.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app