Best Protocol for the Sit-to-Stand Test in Subjects With COPD.

Respiratory Care 2018 August
BACKGROUND: Different protocols for the sit-to-stand test (STS) are available for assessing functional capacity in COPD. We sought to correlate each protocol of the STS (ie, the 5-repetition [5-rep STS], the 30-s STS, and the 1-min STS) with clinical outcomes in subjects with COPD. We also aimed to compare the 3 protocols of the STS, to verify their association and agreement, and to verify whether the 3 protocols are able to predict functional exercise capacity and physical activity in daily life (PADL).

METHODS: 23 subjects with COPD (11 men; FEV1 53 ± 15% predicted) performed 3 protocols of the STS. Subjects also underwent the following assessments: incremental shuttle walking test, 6-min walk test (6MWT), 4-m gait speed test (4MGS), 1-repetition maximum of quadriceps muscle, assessment of PADL, and questionnaires on health-related quality of life and functional status.

RESULTS: The 1-min STS showed significant correlations with the 6MWT (r = 0.40), 4MGS (r = 0.64), and PADL (0.40 ≤ r ≤ 0.52), and the 5-rep STS and 30-s STS were associated with the 4MGS (r = 0.54 and r = 0.52, respectively). The speed differed for each protocol (5-rep STS 0.53 ± 0.16 rep/s, 30-s STS 0.48 ± 0.13 rep/s, 1-min STS 0.45 ± 0.11 rep/s, P = .01). However, they presented good agreement (intraclass correlation coefficient ≥ 0.73 for all) and correlated well with each other (r ≥ 0.68 for all). More marked changes in peripheral oxygen saturation ( P = .004), heart rate ( P < .001), blood pressure ( P < .001), dyspnea ( P < .001), and leg fatigue ( P < .001) were found after the 1-min STS protocol. Furthermore, the 3 protocols were equally able to identify subjects with low exercise capacity or preserved exercise capacity.

CONCLUSIONS: The 1-min STS generated higher hemodynamic demands and correlated better with clinical outcomes in subjects with COPD. Despite the difference in speed performance and physiological demands between the 5-rep STS and 1-min STS, there was a good level of agreement among the 3 protocols. In addition, all 3 tests were able to identify subjects with low exercise capacity or preserved exercise capacity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app