Add like
Add dislike
Add to saved papers

GHEP-ISFG collaborative exercise on mixture profiles (GHEP-MIX06). Reporting conclusions: Results and evaluation.

One of the main goals of the Spanish and Portuguese-Speaking Group of the International Society for Forensic Genetics (GHEP-ISFG) is to promote and contribute to the development and dissemination of scientific knowledge in the field of forensic genetics. Due to this fact, GHEP-ISFG holds different working commissions that are set up to develop activities in scientific aspects of general interest. One of them, the Mixture Commission of GHEP-ISFG, has organized annually, since 2009, a collaborative exercise on analysis and interpretation of autosomal short tandem repeat (STR) mixture profiles. Until now, six exercises have been organized. At the present edition (GHEP-MIX06), with 25 participant laboratories, the exercise main aim was to assess mixture profiles results by issuing a report, from the proposal of a complex mock case. One of the conclusions obtained from this exercise is the increasing tendency of participating laboratories to validate DNA mixture profiles analysis following international recommendations. However, the results have shown some differences among them regarding the edition and also the interpretation of mixture profiles. Besides, although the last revision of ISO/IEC 17025:2017 gives indications of how results should be reported, not all laboratories strictly follow their recommendations. Regarding the statistical aspect, all those laboratories that have performed statistical evaluation of the data have employed the likelihood ratio (LR) as a parameter to evaluate the statistical compatibility. However, LR values obtained show a wide range of variation. This fact could not be attributed to the software employed, since the vast majority of laboratories that performed LR calculation employed the same software (LRmixStudio). Thus, the final allelic composition of the edited mixture profile and the parameters employed in the software could explain this data dispersion. This highlights the need, for each laboratory, to define through internal validations its criteria for editing and interpreting mixtures, and to continuous train in software handling.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app