We have located links that may give you full text access.
Comparative Study
Controlled Clinical Trial
Journal Article
Validity of the Hum Test, a Simple and Reliable Alternative to the Weber Test.
OBJECTIVES: To compare the diagnostic performance of the Hum Test against the Weber Test using pure tone audiometry (PTA) as the "gold standard" comparator.
METHODS: 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs.
RESULTS: When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference.
CONCLUSION: The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.
METHODS: 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs.
RESULTS: When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference.
CONCLUSION: The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app