Add like
Add dislike
Add to saved papers

Insertion and Presence of Fine-Wire Intramuscular Electrodes to the Lumbar Paraspinal Muscles Do Not Affect Muscle Performance and Activation During High-Exertion Spinal Extension Activities.

BACKGROUND: Low back pain (LBP) is commonly associated with paraspinal muscle dysfunctions. A method to study deep lumbar paraspinal (ie, multifidus) muscle function and neuromuscular activation pattern is intramuscular electromyography (EMG). Previous studies have shown that the procedure does not significantly impact muscle function during activities involving low-level muscle contractions. However, it is currently unknown how muscular function and activation are affected during high-exertion contractions.

OBJECTIVE: To examine the effects of insertion and presence of fine-wire EMG electrodes in the lumbar multifidus on muscle strength, endurance, and activation profiles during high-exertion spinal extension muscle contractions.

DESIGN: Single-blinded, repeated measures intervention trial.

SETTING: University clinical research laboratory PARTICIPANTS: Twenty individuals between the ages of 18-40 free of recent and current back pain.

METHODS: Muscle performance was assessed during 3 conditions (with [WI] and without [WO] presence of intramuscular electrodes, and insertion followed by removal [IO]). Isometric spinal extension strength was assessed with a motorized dynamometer. Muscle endurance was assessed using the Sorensen test with neuromuscular activation profiles analyzed during the endurance test.

MAIN OUTCOME MEASUREMENTS: Spinal extensor muscle strength, endurance, and activation.

RESULTS: Our data showed no significant difference in isometric strength (P = .20) between the 3 conditions. A significant difference in muscle endurance was found (P = .03). Post hoc analysis showed that the muscle endurance in the IO condition was significantly higher than the WO condition (161.3 ± 58.3 versus 142.1 ± 48.2 seconds, P = .04), likely due to a learning effect. All 3 conditions elicited minimal pain (range 0-4/10) and comparable muscle activation profiles.

CONCLUSION: Our findings suggested the sonographically guided insertion and presence of fine-wire intramuscular EMG electrodes in the lumbar multifidus muscles had no significant impact on spinal extension muscle function. This study provides evidence that implementing intramuscular EMG does not affect muscle performance during high-exertion contractions in individuals with no current back pain.

LEVEL OF EVIDENCE: II.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app