We have located links that may give you full text access.
Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water.
Background: Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination.
Methods: Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples ( n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05).
Results: The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa , S. aureus , and C. albicans , respectively) ( P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only ( P < 0.001) although they did not vanish microorganisms completely.
Conclusions: Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.
Methods: Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples ( n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05).
Results: The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa , S. aureus , and C. albicans , respectively) ( P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only ( P < 0.001) although they did not vanish microorganisms completely.
Conclusions: Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app