INTRODUCTION: While diagnostic algorithm using PF4-heparin enzyme-linked immunosorbent assay (ELISA) optical density (OD), and heparin neutralization assay (HNA), or 4T score have been proposed to replace serotonin-release assay (SRA) for heparin-induced thrombocytopenia (HIT), their performance against SRA is unclear. In this study, we proposed and validated the performance of a new algorithm combining PF4-heparin ELISA optical density (OD), HNA and 4T score against SRA for HIT diagnosis.
METHODS: Heparin neutralization assays were performed on specimens submitted for HIT testing with positive PF4-heparin ELISA from December 2015 to September 2017, which were separated into a "training" and a "validation" data set. 4T scores were calculated for ELISA positive cases.
RESULTS: A total of 123 consecutive unique patient samples had positive PF4-heparin ELISA with also HNA data, SRA data, and 4T scores available. Compared to SRA, a "laboratory criteria" (ELISA OD ≥ 1.4 and HNA ≥ 70%) had a sensitivity of 88% (14/16) and specificity of 91% (42/46), and a "combined criteria" (4T score = 8, or 4T score = 6 or 7 and ELISA OD ≥ 1.0, or 4T score = 4 or 5 and ELISA OD ≥ 2.0) had a sensitivity of 75% (12/16) and specificity of 98% (45/46) in the training data set. Laboratory and combined criteria had 90% (56/62) concordance rate. Importantly, for these concordant cases, the diagnostic specificity is 100% (46/46). Based on the data, a novel diagnostic algorithm combining these 2 criteria was proposed and validated prospectively.
CONCLUSION: A novel algorithm has high diagnostic accuracy and potentially could eliminate the need for SRA testing in at least 90% patients with suspected HIT.
METHODS: Heparin neutralization assays were performed on specimens submitted for HIT testing with positive PF4-heparin ELISA from December 2015 to September 2017, which were separated into a "training" and a "validation" data set. 4T scores were calculated for ELISA positive cases.
RESULTS: A total of 123 consecutive unique patient samples had positive PF4-heparin ELISA with also HNA data, SRA data, and 4T scores available. Compared to SRA, a "laboratory criteria" (ELISA OD ≥ 1.4 and HNA ≥ 70%) had a sensitivity of 88% (14/16) and specificity of 91% (42/46), and a "combined criteria" (4T score = 8, or 4T score = 6 or 7 and ELISA OD ≥ 1.0, or 4T score = 4 or 5 and ELISA OD ≥ 2.0) had a sensitivity of 75% (12/16) and specificity of 98% (45/46) in the training data set. Laboratory and combined criteria had 90% (56/62) concordance rate. Importantly, for these concordant cases, the diagnostic specificity is 100% (46/46). Based on the data, a novel diagnostic algorithm combining these 2 criteria was proposed and validated prospectively.
CONCLUSION: A novel algorithm has high diagnostic accuracy and potentially could eliminate the need for SRA testing in at least 90% patients with suspected HIT.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app