Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Extent of Microstructural Tissue Damage Correlates with Hemodynamic Failure in High-Grade Carotid Occlusive Disease: An MRI Study Using Quantitative T2 and DSC Perfusion.

BACKGROUND AND PURPOSE: Chronic hemodynamic impairment in high-grade carotid occlusive disease is thought to cause microstructural abnormalities that might be subclinical or lead to subtle symptoms including cognitive impairment. Quantitative MR imaging allows assessing pathologic structural changes beyond macroscopically visible tissue damage. In this study, high-resolution quantitative T2 mapping combined with DSC-based PWI was used to investigate quantitative T2 changes as a potential marker of microstructural damage in relation to hemodynamic impairment in patients with unilateral high-grade carotid occlusive disease.

MATERIALS AND METHODS: Eighteen patients with unilateral high-grade ICA or MCA stenosis/occlusion were included in the study. T2 values and deconvolved perfusion parameters, including relative CBF, relative CBV, and the relative CBF/relative CBV ratio as a potential indicator of local cerebral perfusion pressure, were determined within areas with delayed TTP and compared with values from contralateral unaffected areas after segmentation of normal-appearing hypoperfused WM and cortical regions. Hemispheric asymmetry indices were calculated for all parameters.

RESULTS: Quantitative T2 was significantly prolonged ( P < .01) in hypoperfused tissue and correlated significantly ( P < .01) with TTP delay and relative CBF/relative CBV reduction in WM. Significant correlations ( P < .001) between TTP delay and the relative CBF/relative CBV ratio were found both in WM and in cortical areas.

CONCLUSIONS: Quantitative T2 can be used as a marker of microstructural tissue damage even in normal-appearing GM and WM within a vascular territory affected by high-grade carotid occlusive disease. Furthermore, the extent of damage correlates with the degree of hemodynamic failure measured by DSC perfusion parameters.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app