We have located links that may give you full text access.
Assessment of Coronal Spinal Alignment for Adult Spine Deformity Cases After Intraoperative T Square Shaped Use.
Spine Deformity 2018 May
STUDY DESIGN: Retrospectively reviewed surgeries between 2011 and 2015 of patients who underwent posterior spinal deformity instrumentation with constructs involving fusions to pelvis and encompassing at least five levels.
OBJECTIVE: Measure the radiographic outcomes of coronal malalignment (CM) after use of an intraoperative T square shaped instrument in posterior spinal deformity surgeries with at least five levels of fusion and extension to pelvis.
BACKGROUND: Neuromuscular children found to benefit from intraoperative T square technique to help achieve proper coronal spinal balance with extensive fusions. This intraoperative technique used in our posterior spine deformity instrumentation surgeries with the aforementioned parameters.
METHODS: There were 50 patients: n = 16 with intraoperative T square and n = 34 no-T square shaped device. Subgroups divided based on greater than 20 mm displacement and greater than 40 mm displacement of the C7 plumb line to the central sacral vertical line on either side in preoperative radiographs. We analyzed the demographics and the pre- and postoperative radiographic parameters of standing films: standing CM (displacement of C7 plumb line to central sacral vertical line), and major coronal Cobb angles in total sample and subgroups and compared T square shaped device with no-T square shaped device use by analysis of variance. A p value ≤.05 is statistically significant.
RESULTS: In the total sample, though postoperative CM mean was not statistically different, we observed greater CM corrections in patients where a T square shaped device was used (70%) versus no-T square shaped device used (18%). In >20 mm and >40 mm subgroups, the postoperative mean CM values were statistically lower for the patients where a T square shaped device was used, p = .016 and p = .003, respectively. Cobb corrections were statistically higher for T square shaped device use in both >20 mm and >40 mm subgroups, 68%, respectively.
CONCLUSION: The intraoperative T square shaped device technique had a positive effect on the amount of spine coronal malalignment correction after its use and for lumbar and thoracic coronal Cobb angles.
LEVEL OF EVIDENCE: Level III.
OBJECTIVE: Measure the radiographic outcomes of coronal malalignment (CM) after use of an intraoperative T square shaped instrument in posterior spinal deformity surgeries with at least five levels of fusion and extension to pelvis.
BACKGROUND: Neuromuscular children found to benefit from intraoperative T square technique to help achieve proper coronal spinal balance with extensive fusions. This intraoperative technique used in our posterior spine deformity instrumentation surgeries with the aforementioned parameters.
METHODS: There were 50 patients: n = 16 with intraoperative T square and n = 34 no-T square shaped device. Subgroups divided based on greater than 20 mm displacement and greater than 40 mm displacement of the C7 plumb line to the central sacral vertical line on either side in preoperative radiographs. We analyzed the demographics and the pre- and postoperative radiographic parameters of standing films: standing CM (displacement of C7 plumb line to central sacral vertical line), and major coronal Cobb angles in total sample and subgroups and compared T square shaped device with no-T square shaped device use by analysis of variance. A p value ≤.05 is statistically significant.
RESULTS: In the total sample, though postoperative CM mean was not statistically different, we observed greater CM corrections in patients where a T square shaped device was used (70%) versus no-T square shaped device used (18%). In >20 mm and >40 mm subgroups, the postoperative mean CM values were statistically lower for the patients where a T square shaped device was used, p = .016 and p = .003, respectively. Cobb corrections were statistically higher for T square shaped device use in both >20 mm and >40 mm subgroups, 68%, respectively.
CONCLUSION: The intraoperative T square shaped device technique had a positive effect on the amount of spine coronal malalignment correction after its use and for lumbar and thoracic coronal Cobb angles.
LEVEL OF EVIDENCE: Level III.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app