Relative Bioavailability of a Single 4-mg Dose of Somatropin Administered by Subcutaneous Injection or by Needle-free Device and Coadministered With the Growth Hormone Inhibitor Octreotide Acetate in Healthy Adult Subjects.

PURPOSE: Somatropin, used to treat growth hormone deficiency, has been traditionally administered by subcutaneous (SC) injection with needle and syringe. Needle-free devices offer ease of administration and may improve adherence and outcomes. This study evaluated the relative bioavailability of somatropin delivered with a needle-free device compared with traditional SC injection.

METHODS: In this randomized, single-dose, crossover study, healthy adults aged 18 to 35 years received single 4-mg doses of somatropin via a needle-free device or SC injection, along with octreotide to suppress endogenous growth hormone production. Blood samples were analyzed for serum somatropin and insulin-like growth factor-1 (IGF-1) concentrations over 24 hours after somatropin dosing. Pharmacokinetic and pharmacodynamic parameters were evaluated by using noncompartmental methods, and bioequivalence was determined based on ln transformation of the AUC0-24 , AUC0-∞ , Cmax , area under the effect-time curve from time 0 to 24 hours (AUEC0-24 ), and maximum effect concentration (Emax ). Bioequivalence was concluded if the 90% CIs of the needle-free device compared with the SC injection, constructed by using the two 1-sided hypotheses at the α = 0.05 level, for these pharmacokinetic/pharmacodynamic parameters fell within the 80.00% to125.00% regulatory acceptance range.

FINDINGS: A total of 57 subjects completed both study periods and were included in the pharmacokinetic analyses. Point estimates (90% CIs) of the geometric mean ratio (needle-free device/SC injection) based on serum somatropin were 1.013 (0.987-1.040) for AUC0-24 , 1.012 (0.986-1.038) for AUC0-∞ , and 1.200 (1.137-1.267) for Cmax . For IGF-1, baseline-corrected point estimates (90% CIs) were 0.901 (0.818-0.993) for AUEC0-24 and 0.867 (0.795-0.946) for Emax . Non-baseline-corrected values were 0.978 (0.953-1.004) for AUEC0-24 and 0.953 (0.923-0.984) for Emax . Both treatments were well tolerated; blood glucose levels increased in nearly all subjects (98.3%). All adverse events were mild and resolved spontaneously within 24 hours.

IMPLICATIONS: Bioequivalence was shown for a single 4-mg dose of somatropin delivered by using a needle-free device compared with SC injection based on ln-transformed AUC0-24 and AUC0-∞ but not ln-transformed Cmax .

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app