We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
[Comparative study on image quality of third-generation dual-source CT pulmonary angiography combined with advanced modeled iterative reconstruction].
Zhonghua Yi Xue za Zhi [Chinese medical journal] 2018 April 4
Objective: To quantitatively evaluate the quality of advanced modeled iterative reconstruction (ADMIRE) combined with 70 kVp and linear blending images in low dose dual energy (70 kVp/sn150 kVp) pulmonary angiography. Methods: A total of 74 cases with normal BMI underwent dual-source CT dual-energy pulmonary angiography with small amount of contrast medium (30 ml) from 2015 to 2017 from the First Affiliated Hospital of Zhengzhou University were randomly assigned to protocol Ⅰ(100 kVp/sn140 kVp) or protocol Ⅱ(70 kVp/sn150 kVp). 70 kVp+ ADMIRE (group 1), linear blending+ ADMIRE (group 2), 100 kVp+ SAFIRE (group 3) images were obtained. CT value and noise standard deviation (SD) of pulmonary arteries were measured in pulmonary trunk artery, left pulmonary artery and left superior pulmonary artery, then SNR and CNR were calculated. Radiation dose parameters (CTDIvol, DLP) were recorded. Results: CT values of pulmonary artery of group 1 were significantly higher than those in group 2 and 3 (both P <0.05). In group 2, SD value of pulmonary artery was lower than that of group 1 and 3(both P <0.05). SD value of pulmonary trunk and left pulmonary artery in group 1 was higher than that in group 3 ( P <0.05), SD value of left superior pulmonary artery had no significant difference between group 1 and group 3 ( P >0.05). SNR and CNR value in group 1 and group 2 had no statistical difference, but they were both higher than that in group 3 (both P <0.05). The effective dose of protocolⅠwas 46% lower than protocol Ⅱ. Conclusion: ADMIRE combined with 70 kVp and linear blending images are better than SAFIRE combined with 100 kVp images, and radiation dose is reduced.70 kVp/sn150 kVp with small amount of contrast medium (30 ml) is a feasible dual energy pulmonary artery scanning protocol.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app