We have located links that may give you full text access.
JOURNAL ARTICLE
VALIDATION STUDY
Validation of a New Device for Measuring Isolated Gastrocnemius Contracture and Evaluation of the Reliability of the Silfverskiöld Test.
Foot & Ankle International 2018 August
BACKGROUND: Important aspects on the diagnostics of isolated gastrocnemius contractures (IGCs) have been poorly described. This study was designed to validate a new ankle range of motion (ROM) measuring device for diagnosing an IGC. In addition, we wanted to investigate the reliability of the clinical Silfverskiöld test.
METHODS: Twelve health care personnel (24 feet) were examined by 4 testers on 3 different occasions for the reliability testing of the new ankle ROM measuring device. The same participants were examined using the Silfverskiöld test to examine the reliability of the clinical test. Eleven patients (15 feet) with IGC were examined before gastrocnemius recession, immediately after surgery, and 3 months after surgery to examine the validity and responsiveness of the ankle ROM device.
RESULTS: An intraclass correlation coefficient (ICC) >0.85 was found for both inter- and intrarater reliability for the new ankle ROM device. The device confirmed an IGC in 13 of 15 feet before surgery and 3 of 13 feet at 3-month follow-up. At baseline, the measured ankle dorsiflexion was median 3 degrees with the knee in extension, which increased to 10 degrees ( P < .001) immediately after surgery and 12 degrees ( P = .003) at 3-month follow-up. ICC values of 0.230 to 0.791 were observed for the inter- and intrarater reliability testing of the clinical Silfverskiöld test.
CONCLUSION: The new ankle ROM measuring device was reliable and responsive for detecting IGC. The Silfverskiöld test had poor inter- and intrarater reliability. Level of evidence Level II, prospective cohort study.
METHODS: Twelve health care personnel (24 feet) were examined by 4 testers on 3 different occasions for the reliability testing of the new ankle ROM measuring device. The same participants were examined using the Silfverskiöld test to examine the reliability of the clinical test. Eleven patients (15 feet) with IGC were examined before gastrocnemius recession, immediately after surgery, and 3 months after surgery to examine the validity and responsiveness of the ankle ROM device.
RESULTS: An intraclass correlation coefficient (ICC) >0.85 was found for both inter- and intrarater reliability for the new ankle ROM device. The device confirmed an IGC in 13 of 15 feet before surgery and 3 of 13 feet at 3-month follow-up. At baseline, the measured ankle dorsiflexion was median 3 degrees with the knee in extension, which increased to 10 degrees ( P < .001) immediately after surgery and 12 degrees ( P = .003) at 3-month follow-up. ICC values of 0.230 to 0.791 were observed for the inter- and intrarater reliability testing of the clinical Silfverskiöld test.
CONCLUSION: The new ankle ROM measuring device was reliable and responsive for detecting IGC. The Silfverskiöld test had poor inter- and intrarater reliability. Level of evidence Level II, prospective cohort study.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app