Add like
Add dislike
Add to saved papers

The risk of violating the posterior malleolar fracture when nailing the ipsilateral concomitant spiral distal tibial fracture.

BACKGROUND: For a distal tibial spiral fracture combined with a non-displaced posterior malleolar fragment (PMF), we proposed a hypothesis that the treating surgeon could assess the size of the PMF to determine the need for stabilizing that structure first before rodding the tibia.

MATERIALS AND METHODS: Fifty 3-D models (22 females) of combined distal tibial and posterior malleolar fractures from one trauma center were reconstructed. In each case, a virtual tibial intramedullary nail (vIM nail) with three distal anteroposterior (AP) locking screws (S13 , S15 and S37 , the number indicating the distance from the screw to the nail tip) were inserted into the center of the tibial canal and ended on top of the distal tibial physeal scar. Contact between the screws and the PMF was defined as causing PMF displacement. The relationship between PMF secondary displacement and traumatic anatomic factors (the fragment area and height of the PMF) was explored. Then, the parameters were justified by analyzing intraoperative radiographs of 35 cases treated by nail with single locking screw (S15 ) design.

RESULTS: In the analog experiment, multiple logistic regression analysis revealed that the height of the PMF could confidently predict the risk of fragment displacement (S13 : odds ratio [OR] 1.18, 95% confidence interval [CI] 1.06-1.32; S15 : OR 1.15, 95% CI 1.05-1.27). Regarding the height of the PMF, the receiver operating characteristic established a cut-off value of 31.2 mm for preliminary fixation of the fragment with 88.89% sensitivity and 88.89% specificity. In the operation group the nail stopped on the top of distal tibial physeal scar, no PMF secondary displacement occurred when the PMF height was less than 31.2 mm. However, the incidence of secondary displacement was 93.33% when the height of the PMF exceeded 31.2 mm.

CONCLUSION: When the distal tibial physeal scare was set as the limit of nail insertion depth, the height of the PMF could be used as a reliable reference predicting the risk of PMF secondary displacement caused by distal anteroposterior locking screw.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app