Dual-Energy Computed Tomography in Patients With Small Hepatocellular Carcinoma: Utility of Noise-Reduced Monoenergetic Images for the Evaluation of Washout and Image Quality in the Equilibrium Phase.
Journal of Computer Assisted Tomography 2018 November
PURPOSE: This study aimed to evaluate the utility of virtual monoenergetic images for detecting washout of small (≤2 cm) hepatocellular carcinoma (HCC) in the equilibrium phase.
METHODS: We performed 120-kVp-equivalent linear-blended (M120) and monoenergetic reconstructions from 40 to 90 keV by standard (40, 50, 60, 70, 80, 90) and novel noise-reduced (nMERA: 40+, 50+, 60+, 70+, 80+, 90+) monoenergetic reconstruction algorithms. Image quality and tumor visibility of delayed washout of HCCs in the equilibrium phase were compared between standard monoenergetic reconstruction algorithm and nMERA by objective and subjective analyses.
RESULTS: Contrast-to-noise ratio of the tumor at 40+ was the highest, whereas the score of tumor visibility peaked at 50+. The score of overall image quality at 40+ was significantly lower than those on all other image series, and the image quality among other image series were not significantly different.
CONCLUSIONS: Virtual monoenergetic image reconstructed with nMERA 50+ was most appropriate to detect washout of small HCCs.
METHODS: We performed 120-kVp-equivalent linear-blended (M120) and monoenergetic reconstructions from 40 to 90 keV by standard (40, 50, 60, 70, 80, 90) and novel noise-reduced (nMERA: 40+, 50+, 60+, 70+, 80+, 90+) monoenergetic reconstruction algorithms. Image quality and tumor visibility of delayed washout of HCCs in the equilibrium phase were compared between standard monoenergetic reconstruction algorithm and nMERA by objective and subjective analyses.
RESULTS: Contrast-to-noise ratio of the tumor at 40+ was the highest, whereas the score of tumor visibility peaked at 50+. The score of overall image quality at 40+ was significantly lower than those on all other image series, and the image quality among other image series were not significantly different.
CONCLUSIONS: Virtual monoenergetic image reconstructed with nMERA 50+ was most appropriate to detect washout of small HCCs.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app