In vivo heterotopic culturing of prefabricated tendon grafts with mechanical stimulation in a sheep model.
Knee 2018 June
BACKGROUND: The goal of this study is to investigate the biomechanical and histological properties of in vivo heterotopically prefabricated cruciate ligament replacement grafts with and without mechanical stimulation. The clinical goal is to heterotopically prefabricate a bone-tendon-bone graft for anterior cruciate ligament reconstruction, which allows rapid ingrowth and early full weight bearing.
METHODS: In a sheep model, eight quadriceps tendon grafts were harvested and introduced into culture chambers at their proximal and distal ends. In group S, four tendon-chamber constructs were mechanically stimulated by direct attachment to the quadriceps tendon and patella. In group NS, the same constructs were cultured without proximal attachment. All sheep were sacrificed six weeks postoperatively and the constructs were examined biomechanically and histologically. The healthy contralateral ACL and quadriceps tendon were used as controls.
RESULTS: Macroscopically, no obvious ossification could be observed at the ends of the tendon-chamber constructs six weeks postoperatively. Histologically, the tendon tissue from the mechanically stimulated constructs revealed higher counts of cells and capillaries. However, there was less regular cell distribution and collagen fiber orientation compared to the control group. In addition, osteoblasts and osteogenesis were observed in the prefabricated constructs both with and without mechanical stimulation. Biomechanically, there were no significant differences in stiffness, elongation and ultimate failure load between the groups.
CONCLUSION: In vivo heterotopic culture of prefabricated tendon grafts may have the potential to stimulate osteoblasts and induce osteogenesis. Future studies with longer follow-up and modifications of the surgical technique and culture conditions are desirable.
METHODS: In a sheep model, eight quadriceps tendon grafts were harvested and introduced into culture chambers at their proximal and distal ends. In group S, four tendon-chamber constructs were mechanically stimulated by direct attachment to the quadriceps tendon and patella. In group NS, the same constructs were cultured without proximal attachment. All sheep were sacrificed six weeks postoperatively and the constructs were examined biomechanically and histologically. The healthy contralateral ACL and quadriceps tendon were used as controls.
RESULTS: Macroscopically, no obvious ossification could be observed at the ends of the tendon-chamber constructs six weeks postoperatively. Histologically, the tendon tissue from the mechanically stimulated constructs revealed higher counts of cells and capillaries. However, there was less regular cell distribution and collagen fiber orientation compared to the control group. In addition, osteoblasts and osteogenesis were observed in the prefabricated constructs both with and without mechanical stimulation. Biomechanically, there were no significant differences in stiffness, elongation and ultimate failure load between the groups.
CONCLUSION: In vivo heterotopic culture of prefabricated tendon grafts may have the potential to stimulate osteoblasts and induce osteogenesis. Future studies with longer follow-up and modifications of the surgical technique and culture conditions are desirable.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app