Rate of contamination of hospital privacy curtains in a burns/plastic ward: A longitudinal study.
American Journal of Infection Control 2018 September
BACKGROUND: Since hospital patient privacy curtains can harbor bacteria, are high-touch surfaces, and are cleaned infrequently, they may be involved in pathogen transmission. The aim of this longitudinal prospective study was to understand curtain contamination to inform curtain hygiene protocols, thereby minimizing the role of curtains in pathogen transmission.
METHODS: Over 21 days, cultures of 10 freshly laundered curtains (8 test curtains surrounding patient beds and 2 controls in an unoccupied staff room) were taken in the Regional Burns/Plastics Unit. Contact plates were used to sample the curtains near the edge hem where they are most frequently touched. Microbial contamination and the presence of methicillin-resistant Staphylococcus aureus (MRSA) were determined.
RESULTS: By day 3, test curtains showed increased microbial contamination (mean colony-forming units [CFU]/cm2 = 1.17) compared to control curtains (mean CFU/cm2 = 0.19). Test curtains became increasingly contaminated over time, with mean CFU/cm2 for days 17 and 21 of 1.86 and 5.11, respectively. By day 10, 1/8 test curtains tested positive for MRSA, and 5/8 were positive by day 14.
CONCLUSIONS: Patient privacy curtains became progressively contaminated with bacteria, including MRSA. Between days 10 and 14 after being hung, curtains showed increased MRSA positivity. This may represent an opportune time to intervene, either by cleaning or replacing the curtains.
METHODS: Over 21 days, cultures of 10 freshly laundered curtains (8 test curtains surrounding patient beds and 2 controls in an unoccupied staff room) were taken in the Regional Burns/Plastics Unit. Contact plates were used to sample the curtains near the edge hem where they are most frequently touched. Microbial contamination and the presence of methicillin-resistant Staphylococcus aureus (MRSA) were determined.
RESULTS: By day 3, test curtains showed increased microbial contamination (mean colony-forming units [CFU]/cm2 = 1.17) compared to control curtains (mean CFU/cm2 = 0.19). Test curtains became increasingly contaminated over time, with mean CFU/cm2 for days 17 and 21 of 1.86 and 5.11, respectively. By day 10, 1/8 test curtains tested positive for MRSA, and 5/8 were positive by day 14.
CONCLUSIONS: Patient privacy curtains became progressively contaminated with bacteria, including MRSA. Between days 10 and 14 after being hung, curtains showed increased MRSA positivity. This may represent an opportune time to intervene, either by cleaning or replacing the curtains.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app