We have located links that may give you full text access.
Spatial orientation of coronary arteries and its implication for breast and thoracic radiotherapy-proposing "coronary strip" as a new organ at risk.
OBJECTIVES: Radiotherapy for breast cancer has been associated with various side effects including cardiac sequelae. Our study aimed to define the spatial arc of spread of coronary vessels in a radian angle.
MATERIALS AND METHODS: We analysed the records of 51 CT coronary angiographies done in our hospital from January 2016 to July 2016. Left anterior descending (LAD) and right coronary (RC) were contoured for each patient. In each axial section, the radial spread of each artery was noted. A 5 mm brush tool was used to join the start and stop angles for making the summated "coronary strips".
RESULTS: Start and end angle of LAD with 95% confidence interval (CI) (in clockwise direction) were 23.9 ± 4° and 79.0 ± 6.6°, respectively. Mean LAD arc length ± SD (standard deviation) noted was 55.1° ± 7.7° (95% CI). For RC the smallest start angle and the largest end angle in all patients was 297.6° and 322.6°, respectively. RC start angle, end angle and arc length for 95% confidence interval were 322.2 ± 6.1°, 292.4 ± 11.6° and 29.8 ± 13.1°, respectively.
CONCLUSIONS: Our study provides a measure of the radial spread of the coronary arteries, especially from the perspective of breast radiotherapy. We have proposed a new organ at risk (OAR) of coronary strip. This should provide an easy and cost-effective way to delineate the coronary vasculature in breast cancer patients undergoing radiotherapy.
MATERIALS AND METHODS: We analysed the records of 51 CT coronary angiographies done in our hospital from January 2016 to July 2016. Left anterior descending (LAD) and right coronary (RC) were contoured for each patient. In each axial section, the radial spread of each artery was noted. A 5 mm brush tool was used to join the start and stop angles for making the summated "coronary strips".
RESULTS: Start and end angle of LAD with 95% confidence interval (CI) (in clockwise direction) were 23.9 ± 4° and 79.0 ± 6.6°, respectively. Mean LAD arc length ± SD (standard deviation) noted was 55.1° ± 7.7° (95% CI). For RC the smallest start angle and the largest end angle in all patients was 297.6° and 322.6°, respectively. RC start angle, end angle and arc length for 95% confidence interval were 322.2 ± 6.1°, 292.4 ± 11.6° and 29.8 ± 13.1°, respectively.
CONCLUSIONS: Our study provides a measure of the radial spread of the coronary arteries, especially from the perspective of breast radiotherapy. We have proposed a new organ at risk (OAR) of coronary strip. This should provide an easy and cost-effective way to delineate the coronary vasculature in breast cancer patients undergoing radiotherapy.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app