We have located links that may give you full text access.
Increased microvolt T-wave alternans in children and adolescents with Eisenmenger syndrome.
Anatolian Journal of Cardiology 2018 April 11
OBJECTIVE: To determine the values of microvolt T-wave alternans (MTWA) in children and adolescents with Eisenmenger syndrome (ES) and controls.
METHODS: Thirteen were included in the study. After analyzing the 24-h ECG recordings, MTWA was considered using three leads (V5, V1, and aVF). Right heart catheterization and 6-minute walk test (6-MWD) were applied to the patients and pro-brain natriuretic peptide levels were assessed; echocardiographic parameters were obtained from both the groups and the results were compared.
RESULTS: The MTWA value in lead V5 was 81.08±10.73 µV in the patient group (63.50±18.78 µV in the control group), in lead V1 was 75.00±16.86 µV (73.94±16.77 µV in the control group), and in lead aVF was 73.77±17.81 µV (72.61±16.21 µV in the control group). Comparison of MTWA values between patients and controls revealed that only lead V5 values were statistically different in the ES group. The 6-MWD scores significantly correlated with lead V5. Right atrial volume and right ventricular fractional area change were significantly correlated with lead V1. The Tei index was significantly correlated with lead aVF.
CONCLUSION: The MTWA lead V5 value was significantly higher in children with ES than in controls and was also correlated with decreased exercise tolerance.
METHODS: Thirteen were included in the study. After analyzing the 24-h ECG recordings, MTWA was considered using three leads (V5, V1, and aVF). Right heart catheterization and 6-minute walk test (6-MWD) were applied to the patients and pro-brain natriuretic peptide levels were assessed; echocardiographic parameters were obtained from both the groups and the results were compared.
RESULTS: The MTWA value in lead V5 was 81.08±10.73 µV in the patient group (63.50±18.78 µV in the control group), in lead V1 was 75.00±16.86 µV (73.94±16.77 µV in the control group), and in lead aVF was 73.77±17.81 µV (72.61±16.21 µV in the control group). Comparison of MTWA values between patients and controls revealed that only lead V5 values were statistically different in the ES group. The 6-MWD scores significantly correlated with lead V5. Right atrial volume and right ventricular fractional area change were significantly correlated with lead V1. The Tei index was significantly correlated with lead aVF.
CONCLUSION: The MTWA lead V5 value was significantly higher in children with ES than in controls and was also correlated with decreased exercise tolerance.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app