We have located links that may give you full text access.
Effect of pulsed ultrasound toothbrush on Streptococcus mutans biofilm removal.
American Journal of Dentistry 2018 April
PURPOSE: To evaluate the effect of pulsed ultrasound toothbrush on the removal of biofilm formed by Streptococcus mutans (S. mutans).
METHODS: S. mutans biofilm grown on apatite pellet was destructed with four different sonic action toothbrushes: 1) pulsed ultrasound with sonic vibration (PUV); 2) continuous ultrasound with sonic vibration (CUV); 3) sonic vibration only (SV); and 4) no ultrasound nor sonic vibration (control). After 3 minutes of noncontact brushing, the amount of water-insoluble glucan was measured, and the residual biofilm was observed by scanning electron microscopy.
RESULTS: PUV group revealed the smallest amount of the residual water-insoluble glucans (32 ± 19%), followed by the CUV group (54 ± 12%) and the SV group (64 ± 13%). The PUV group showed a significantly lower amount of the residual water-insoluble glucan than the SV group, while no significant difference was found between SV and CUV. The bacterial adherence and aggregation notably decreased in the PUV group, compared to the remaining three groups.
CLINICAL SIGNIFICANCE: The sonic vibration with pulsed ultrasound showed more reduction of the biofilm compared to the control and the sonic vibration with and without continuous ultrasound. Thus, pulsed ultrasound action may be beneficial for biofilm removal of interproximal regions.
METHODS: S. mutans biofilm grown on apatite pellet was destructed with four different sonic action toothbrushes: 1) pulsed ultrasound with sonic vibration (PUV); 2) continuous ultrasound with sonic vibration (CUV); 3) sonic vibration only (SV); and 4) no ultrasound nor sonic vibration (control). After 3 minutes of noncontact brushing, the amount of water-insoluble glucan was measured, and the residual biofilm was observed by scanning electron microscopy.
RESULTS: PUV group revealed the smallest amount of the residual water-insoluble glucans (32 ± 19%), followed by the CUV group (54 ± 12%) and the SV group (64 ± 13%). The PUV group showed a significantly lower amount of the residual water-insoluble glucan than the SV group, while no significant difference was found between SV and CUV. The bacterial adherence and aggregation notably decreased in the PUV group, compared to the remaining three groups.
CLINICAL SIGNIFICANCE: The sonic vibration with pulsed ultrasound showed more reduction of the biofilm compared to the control and the sonic vibration with and without continuous ultrasound. Thus, pulsed ultrasound action may be beneficial for biofilm removal of interproximal regions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app