BACKGROUND: A rare complication following tracheotomy is common carotid artery (CCA) pseudoaneurysm. Treatment modalities for CCA pseudoaneurysm include surgical repair and single-artery balloon-covered stent graft technique. We describe successful treatment of tracheotomy-related CCA pseudoaneurysm with the "kissing balloon" expandable stent graft technique.
CASE DESCRIPTION: We successfully implemented the kissing balloon expandable stent graft technique for treatment of a large, narrow-necked, bilobed CCA pseudoaneurysm that arose owing to a tracheotomy complication. The pseudoaneurysm was detected while performing a diagnostic angiogram of the aortic arch and surrounding vessels. The stent was deployed while the 2 balloons were introduced in a kissing manner such that they faced one another to avoid occlusion of either branch of the innominate artery coming into contact; 1 balloon was inflated at the origin of the right subclavian artery, and the other was inflated at the right innominate artery simultaneously. The pseudoaneurysm was successfully contained; normal blood flow was restored in the CCA. The balloons were deflated and withdrawn. The patient remained neurologically intact after the procedure.
CONCLUSIONS: The kissing balloon technique is a safe and effective alternative to surgical repair, as it prevents morbidities associated with the surgical procedure. Also, this technique decreases the risk of major side-branch occlusion associated with the single-artery balloon-covered stent graft technique.
CASE DESCRIPTION: We successfully implemented the kissing balloon expandable stent graft technique for treatment of a large, narrow-necked, bilobed CCA pseudoaneurysm that arose owing to a tracheotomy complication. The pseudoaneurysm was detected while performing a diagnostic angiogram of the aortic arch and surrounding vessels. The stent was deployed while the 2 balloons were introduced in a kissing manner such that they faced one another to avoid occlusion of either branch of the innominate artery coming into contact; 1 balloon was inflated at the origin of the right subclavian artery, and the other was inflated at the right innominate artery simultaneously. The pseudoaneurysm was successfully contained; normal blood flow was restored in the CCA. The balloons were deflated and withdrawn. The patient remained neurologically intact after the procedure.
CONCLUSIONS: The kissing balloon technique is a safe and effective alternative to surgical repair, as it prevents morbidities associated with the surgical procedure. Also, this technique decreases the risk of major side-branch occlusion associated with the single-artery balloon-covered stent graft technique.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app